    Digital Clock and Timer

    The ZT1590 digital clock and timer is a complete, microprocessor-based device that displays both time of day and elapsed time information. The ZT1590 has a dual-row, 7-segment display with large, red LED characters, easily read in high ambient light. All features, as well as the device setup, may be carried out with the four, onboard pushbuttons, or on an optionally connected MK1550 clock remote. No DIP switch configuration is required.

    The digital clock on the ZT1590 may be set to 12 hour or 24 hour mode. The time is displayed on the top display. If power is lost to the device, the clock will continue to run (with the display inactive) for at least 24 hours, without loss of time. The elapsed timer begins in minutes/seconds, and will automatically switch over to hours/minutes after reaching 59:59.

    The ZT1590 is a very low-profile device, with a depth of only slightly over 1". An external class 2 power supply (sold separately or as part of a kit) is available, allowing the ZT1590 to be powered by 100-240 VAC. Refer to ZT1590S for a complete, preassembled kit in backbox.

  • Key Features: ZT1590

    • 12/24 hour clock time
    • Elapsed time in minutes/seconds automatically carried over to hours/minutes
    • All device set up and features carried out via connected MK1550 chronometer remote
    • Plugable connectors for simple installation
    • Utilizes external class 2 power supply for low voltage power
    • Power outage backup for at least 24 hours, no batteries required
  • Applications: ZT1590

    • Isolated power systems
    • Healthcare facilities
  • Ordering information: ZT1590

    NameOrdering Number
    ZT1590B511100012
  • Downloads: ZT1590

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    Clocks and Timers
    English 10.2011
    Download
    Installation Bulletin
    ZT1590 / MK1550
    English 08.2011
    Download
  • Accessories: ZT1590

    Power Supplies

    Class 2 Power Supply

    NameOrdering Number
    CP-D12083P13800050
    Remote Indicators

    Clock Remote for BENDER Digital Clocks / Timers

    NameOrdering Number
    MK1550B511100019
  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • ZT1590RS

    Preassembled Digital Clock and Timer Kit

    The ZT1590 digital clock and timer is a complete, microprocessor-based device that displays both time of day and elapsed time information. The ZT1590 has a dual-row, 7-segment display with large, red LED characters, easily read in high ambient light. All features, as well as the device setup, may be carried out with the four, onboard pushbuttons, or on an optionally connected MK1550 clock remote. No DIP switch configuration is required.

    The digital clock on the ZT1590 may be set to 12 hour or 24 hour mode. The time is displayed on the top display. If power is lost to the device, the clock will continue to run (with the display inactive) for at least 24 hours, without loss of time. The elapsed timer begins in minutes/seconds, and will automatically switch over to hours/minutes after reaching 59:59.

    The ZT1590RS is a preassembled kit with clock and power supply, in a backbox with front trim. Refer to ZT1590 for standalone clock and components.

  • Key Features: ZT1590RS

    • 12/24 hour clock time
    • Elapsed time in minutes/seconds automatically carried over to hours/minutes
    • All device set up and features carried out via connected MK1550 chronometer remote
    • Plugable connectors for simple installation
    • Utilizes external class 2 power supply for low voltage power
    • Power outage backup for at least 24 hours, no batteries required
    • Preassembled kit including clock and power supply in backbox with front trim
  • Applications: ZT1590RS

    • Isolated power systems
    • Healthcare facilities
  • Ordering information: ZT1590RS

    NameOrdering Number
    ZT1590RSB521300297
  • Downloads: ZT1590RS

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    Clocks and Timers
    English 10.2011
    Download
    Installation Bulletin
    ZT1590 / MK1550
    English 08.2011
    Download
  • Accessories: ZT1590RS

    Remote Indicators

    Clock Remote for BENDER Digital Clocks / Timers

    NameOrdering Number
    MK1550B511100019
  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • ZT1594

    Surgical Chronometer

    The ZT1594 surgical chronometer is a complete, microprocessor based system that displays time of day and three elapsed times. The system has four seven-segment displays with large, red LED characters easily read in high ambient light. All features, as well as device setup, are carried out on the connected MK1554 chronometer remote.

  • Key Features: ZT1594

    • 12/24 hour clock time
    • Elapsed time in minutes/seconds automatically carried over to hours/minutes
    • All device set up and features carried out via connected MK1554 chronometer remote
    • Plugable connectors for simple installation
    • 100 - 240 VAC supply power input
    • Power outage backup for at least 24 hours, no batteries required
  • Applications: ZT1594

    • Isolated power systems
    • Healthcare facilities
  • Ordering information: ZT1594

    NameOrdering Number
    ZT1594B511100012
  • Downloads: ZT1594

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    Clocks and Timers
    English 10.2011
    Download
  • Accessories: ZT1594

  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • MK1550

    Clock Remote for BENDER Digital Clocks / Timers

    The MK1550 is a clock remote for use with the ZT1590 digital clock and timer. The MK1550 duplicates all functions of the ZT1590 and may be installed in a remote location. The clock may also be set up using the MK1550's four pushbuttons. The timer pushbuttons may be used to pause, resume or reset an elapsed timer when desired. The HOLD/RESUME pushbutton is supplied with a red LED, which flashes when the count is paused.

    The MK1550 mounts in a standard single-gang electrical box.

  • Key Features: MK1550

    • Duplicates all pushbutton and setup features of connected clocks, timers, and chronometers
    • Mounts in standard single-gang electrical box
  • Applications: MK1550

  • Ordering information: MK1550

    NameOrdering Number
    MK1550B511100019
  • Downloads: MK1550

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    Clocks and Timers
    English 10.2011
    Download
    Installation Bulletin
    ZT1590 / MK1550
    English 08.2011
    Download
  • Accessories: MK1550