  • RCM470LY

    Ground fault monitor for grounded and high-resistance grounded AC systems

    The RCM470LY monitors for ground fault current in grounded and high-resistance grounded AC systems, both single-phase and three-phase. The RCM470LY features a steplessly adjustable setpoint from either 6 mA...600 mA or 10 mA...10 A. Display features include power and alarm LEDS, as well as an LED bar graph indicating how close the system is to the alarm value. An adjustable time delay of 0...10 s is available.

    The device may be set to latching or non-latching operation, and features one DPDT alarm relay which may be set to normally energized or normally de-energized operation. An external BENDER current transformer is required for operation.

  • Key Features: RCM470LY

    • Ground fault monitoring for grounded and high-resistance grounded AC systems
    • Adjustable response value ranges, as high as 10 A and as low as 6 mA
    • Many different current transformer sizes available
    • On, alarm, and bar graph LEDs for indicating device status
    • Built-in test and reset button
    • Connections for external test and reset
    • Connection for optional external panel meter
    • Adjustable time delay, 0...10 s
    • Latching or non-latching operation, selectable
    • 1 DPDT Form-C contact output, normally energized or de-energized operation, selectable
  • Applications: RCM470LY

    • Ground fault detection in grounded and high-resistance AC systems
    • Motors and motor control systems
    • Generators, portable and fixed
    • Alarm systems, safety devices
    • General industrial systems
    • Controls and control systems
    • Heat tracing systems
    • Marinas
  • Ordering information: RCM470LY

    NameResponse ValueSupply VoltageOrdering Number
    RCM470LY10 - 10000 mA AC 230 V (50 - 400 Hz) B94012017
    RCM470LY-1310 - 10000 mA AC 90 - 132 V (50 - 400 Hz) B94012019
    RCM470LY-13A10 - 10000 mA AC 90 - 132 V (50 - 60 Hz) B94012019A
    RCM470LY-2110 - 10000 mA DC 9.6 - 84 V B94012021
    RCM470LY-2310 - 10000 mA DC 77 - 286 V B94012024
    RCM470LY-716 - 600 mA AC 230 V (50 - 400 Hz) B94012060
    RCM470LY-71136 - 600 mA AC 90 - 132 V (50 - 400 Hz) B94012051
    RCM470LY-71216 - 600 mA DC 9.6 - 84 V B94012050
  • Downloads: RCM470LY

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    RCM470LY
    English 03.2011
    Download
    Installation Bulletin
    RCM470LY
    English 10.2012
    Download
    Brochure
    Overview of Products
    English 02.2014
    Download
  • Accessories: RCM470LY

    AC Current Transformers

    Current transformers for RCM and RCMS series ground fault monitors (AC only systems)

    NameOrdering Number
    W0-S20B911787
    W1-S35B911731
    W2-S70B911732
    W3-S105B911733
    W4-S140B911734
    W5-S210B911735
    Rectangular AC Current Transformers

    Rectangular current transformers for RCM and RCMS series ground fault monitors (AC only systems)

    NameOrdering Number
    WR70x175B98080609
    WR115x305B98080610
    Split-Core AC Current Transformers

    Split-core current transformers for RCM and RCMS series ground fault monitors (AC only systems)

    NameOrdering Number
    WS20x30B98080601
    WS50x80B98080603
    WS80x120B98080606
    External Meters

    Analog output meters for BENDER devices

    NameOrdering Number
    7204-4241B986805
    9604-4241B986807
  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • RCM475LY

    Ground fault monitor for grounded and high-resistance grounded AC systems

    The RCM475LY monitors for ground fault current in grounded and high-resistance grounded AC systems, both single-phase and three-phase. The RCM475LY features a steplessly adjustable setpoint from either 6 mA...600 mA or 10 mA...10 A. Display features include power and alarm LEDS, as well as an LED bar graph indicating how close the system is to the alarm value. An adjustable time delay of 0...10 s is available.

    The device may be set to latching or non-latching operation, and features one DPDT alarm relay which may be set to normally energized or normally de-energized operation. The RCM475LY includes a built-in current transformer.

  • Key Features: RCM475LY

    • Ground fault monitoring for grounded and high-resistance grounded AC systems
    • Built-in current transformer
    • Adjustable response value ranges, as high as 10 A and as low as 6 mA
    • On, alarm, and bar graph LEDs for indicating device status
    • Built-in test and reset button
    • Connections for external test and reset
    • Connection for optional external panel meter
    • Adjustable time delay, 0...10 s
    • Latching or non-latching operation, selectable
    • 1 DPDT Form-C contact output, normally energized or de-energized operation, selectable
  • Applications: RCM475LY

    • Ground fault detection in grounded and high-resistance AC systems
    • Branch monitoring
    • Motors and motor control systems
    • Generators, portable and fixed
    • Alarm systems, safety devices
    • General industrial systems
    • Controls and control systems
    • Heat tracing systems
    • Marinas
  • Ordering information: RCM475LY

    NameResponse ValueSupply VoltageOrdering Number
    RCM475LY10 - 10000 mA AC 230 V (50 - 60 Hz) B94012018
    RCM475LY-1310 - 10000 mA AC 90 - 132 V (50 - 60 Hz) B94012035
    RCM475LY-2110 - 10000 mA DC 9.6 - 84 V B94012073
    RCM475LY-2310 - 10000 mA DC 77 - 286 V B94012069
    RCM475LY-716 - 600 mA AC 230 V (50 - 60 Hz) B94012052
    RCM475LY-71136 - 600 mA AC 90 - 132 V (50 - 60 Hz) B94012053
    RCM470LY-71216 - 600 mA DC 9.6 - 84 V B94012070
  • Downloads: RCM475LY

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    RCM475LY
    English 03.2011
    Download
    Brochure
    Overview of Products
    English 02.2014
    Download
  • Accessories: RCM475LY

  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • RCM420

    Digital ground fault monitor for grounded and high-resistance grounded AC systems

    The RCM420 monitors for ground fault current in grounded and high-resistance grounded AC systems, both single-phase and three-phase. The RCM420 reads a true RMS value, and displays the read ground fault current in real-time on the built-in digital display. The RCM420 features a steplessly adjustable setpoint from 10 mA to 10 A. Along with the main alarm value, a prewarning alarm, set as a percentage of the main alarm value, may be set.

    All settings for the device are changed via the device's onboard, easy-to-use menu. Three separate time delays may be utilized - a trip delay (0 to 10 s), a startup delay (0 to 10 s), and a delay on release (0 to 99 s). Two SPDT alarm relays may be set to normally energized or normally de-energized operation, and may be set to latching or non-latching operation. An external BENDER current transformer is required for operation.

  • Key Features: RCM420

    • Ground fault monitoring for grounded and high-resistance grounded AC systems
    • True RMS reading
    • Digital display showing ground fault current in real-time
    • Adjustable response value from 10 mA to 10 A
    • Many different current transformer sizes available
    • Built-in test and reset button
    • Connections for external test and reset
    • Optional versions with analog outputs
    • Adjustable time delays for response delay, startup delay, and delay on release
    • Latching or non-latching operation, selectable
    • 2 SPDT Form-C contact outputs, normally energized or de-energized operation, selectable
  • Applications: RCM420

    • Ground fault detection in grounded and high-resistance AC systems
    • Branch monitoring
    • Motors and motor control systems
    • Generators, portable and fixed
    • Alarm systems, safety devices
    • General industrial systems
    • Controls and control systems
    • Heat tracing systems
    • Marinas
  • Ordering information: RCM420

    NameResponse ValueSPDT contact outputSupply VoltageOrdering Number
    RCM420-D-110 - 10000 mA 2AC 16 - 72 V (42 - 460 Hz) DC 9.6 - 94 V B94014001
    RCM420-D-210 - 10000 mA 2AC 70 - 300 V (42 - 460 Hz) DC 70 - 300 V B94014002
  • Downloads: RCM420

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    RCM420
    English 08.2013
    Download
    Installation Bulletin
    RCM420
    English 08.2013
    Download
    Menu Overview / Settings Checklist
    RCM420
    English 08.2013
    Download
    User Manual
    RCM420
    English 03.2012
    Download
    Installation Bulletin
    RCM420-DM
    English 10.2012
    Download
    User Manual
    RCM420-DM
    English 07.2010
    Download
    Brochure
    Overview of Products
    English 02.2014
    Download
    3D STEP Drawing
    420 Series (Standard)
    N/A 06.2013
    Download
  • Accessories: RCM420

    AC Current Transformers

    Current transformers for RCM and RCMS series ground fault monitors (AC only systems)

    NameOrdering Number
    W0-S20B911787
    W1-S35B911731
    W2-S70B911732
    W3-S105B911733
    W4-S140B911734
    W5-S210B911735
    Rectangular AC Current Transformers

    Rectangular current transformers for RCM and RCMS series ground fault monitors (AC only systems)

    NameOrdering Number
    WR70x175B98080609
    WR115x305B98080610
    Split-Core AC Current Transformers

    Split-core current transformers for RCM and RCMS series ground fault monitors (AC only systems)

    NameOrdering Number
    WS20x30B98080601
    WS50x80B98080603
    WS80x120B98080606
  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • RCMA420

    Digital ground fault monitor for grounded and high-resistance grounded AC/DC systems

    This devices meets or exceeds compliance with the upcoming 2014 NEC 250.167(B) code for ground fault detection on grounded DC systems.

    The RCMA420 monitors for ground fault current in grounded and high-resistance grounded AC systems, both single-phase and three-phase, as well as pure DC and mixed AC/DC systems. The RCMA420 reads a true RMS value, and displays the read ground fault current in real-time on the built-in digital display. The RCMA420 features a steplessly adjustable setpoint from 10 mA to 500 mA. Along with the main alarm value, a prewarning alarm, set as a percentage of the main alarm value (50 to 100%), may be set.

    All settings for the device are changed via the device's onboard, easy-to-use menu. Three separate time delays may be utilized - a trip delay (0 to 10 s), a startup delay (0 to 10 s), and a delay on release (0 to 99 s). Two SPDT alarm relays may be set to normally energized or normally de-energized operation, and may be set to latching or non-latching operation. An external BENDER current transformer is required for operation.

    Compatible current transformers include the W20AB, W35AB, and W60AB.

  • Key Features: RCMA420

    • Ground fault monitoring for grounded and high-resistance grounded AC/DC systems
    • True RMS reading
    • Digital display showing ground fault current in real-time
    • Adjustable response value from 10 mA to 500 mA
    • Many different current transformer sizes available
    • Built-in test and reset button
    • Connections for external test and reset
    • Optional versions with analog outputs
    • Adjustable time delays for response delay, startup delay, and delay on release
    • Latching or non-latching operation, selectable
    • 2 SPDT Form-C contact outputs, normally energized or de-energized operation, selectable
  • Applications: RCMA420

    • Ground fault detection in grounded and high-resistance AC/DC systems
    • Branch monitoring
    • Variable frequency drives (VFDs)
    • Batteries and battery backup systems
    • Motors and motor control systems
    • Generators, portable and fixed
    • Alarm systems, safety devices
    • General industrial systems
    • Controls and control systems
    • Heat tracing systems
  • Ordering information: RCMA420

    NameResponse Value0...400 μA analog output0(4)...20 mA analog output0...10 V analog outputSPDT contact outputSupply VoltageOrdering Number
    RCMA420-D-110 - 500 mA 2AC 16 - 72 V (42 - 460 Hz) DC 9.6 - 94 V B94043001
    RCMA420-D-210 - 500 mA 2AC 70 - 300 V (42 - 460 Hz) DC 70 - 300 V B94043002
    RCMA420-DM-110 - 500 mA AC 16 - 72 V (42 - 460 Hz) DC 9.6 - 94 V B94043003
    RCMA420-DM-210 - 500 mA AC 70 - 300 V (42 - 460 Hz) DC 70 - 300 V B94043008
    RCMA420-DM1C-110 - 500 mA 1AC 16 - 72 V (42 - 460 Hz) DC 9.6 - 94 V B94043005
    RCMA420-DM1C-210 - 500 mA 1AC 70 - 300 V (42 - 460 Hz) DC 70 - 300 V B94043010
    RCMA420-DM2C-110 - 500 mA 1AC 16 - 72 V (42 - 460 Hz) DC 9.6 - 94 V B94043006
    RCMA420-DM2C-210 - 500 mA 1AC 70 - 300 V (42 - 460 Hz) DC 70 - 300 V B94043011
    RCMA420-DM3C-110 - 500 mA 1AC 16 - 72 V (42 - 460 Hz) DC 9.6 - 94 V B94043007
    RCMA420-DM3C-210 - 500 mA 1AC 70 - 300 V (42 - 460 Hz) DC 70 - 300 V B94043012
  • Downloads: RCMA420

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    RCMA420
    English 04.2013
    Download
    Installation Bulletin
    RCMA420
    English 10.2012
    Download
    Menu Overview / Settings Checklist
    RCMA420
    English 08.2013
    Download
    User Manual
    RCMA420
    English 03.2011
    Download
    Brochure
    Overview of Products
    English 02.2014
    Download
    3D STEP Drawing
    420 Series (Connector Terminals)
    N/A 06.2013
    Download
  • Accessories: RCMA420

    AC/DC Current Transformers

    Current transformers for RCMA420, RCMA423, and RCMS series ground fault monitors (AC/DC systems)

    NameOrdering Number
    W20ABB98080008
    W35ABB98080016
    W60ABB98080016
    Connector Cables

    Connector cables for RCMA and RCMS series ground fault monitors

    NameOrdering Number
    WX-100B511100033
    WX-250B511100032
    WX-500B511100031
    WX-1000B511100034
  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • RCMA423

    Digital ground fault monitor for grounded and high-resistance grounded AC/DC systems

    This devices meets or exceeds compliance with the upcoming 2014 NEC 250.167(B) code for ground fault detection on grounded DC systems.

    The RCMA423 monitors for ground fault current in grounded and high-resistance grounded AC systems, both single-phase and three-phase, as well as pure DC and mixed AC/DC systems. The RCMA423 reads a true RMS value, and displays the read ground fault current in real-time on the built-in digital display. The RCMA420 features a steplessly adjustable setpoint from 30 mA to 3 A. Along with the main alarm value, a prewarning alarm, set as a percentage of the main alarm value (50 to 100%), may be set.

    All settings for the device are changed via the device's onboard, easy-to-use menu. Three separate time delays may be utilized - a trip delay (0 to 10 s), a startup delay (0 to 10 s), and a delay on release (0 to 99 s). Two SPDT alarm relays may be set to normally energized or normally de-energized operation, and may be set to latching or non-latching operation. An external BENDER current transformer is required for operation.

    Compatible current transformers include the entire WAB series.

  • Key Features: RCMA423

    • Ground fault monitoring for grounded and high-resistance grounded AC/DC systems
    • True RMS reading
    • Digital display showing ground fault current in real-time
    • Adjustable response value from 30 mA to 3 A
    • Many different current transformer sizes available
    • Built-in test and reset button
    • Connections for external test and reset
    • Optional versions with analog outputs
    • Adjustable time delays for response delay, startup delay, and delay on release
    • Latching or non-latching operation, selectable
    • 2 SPDT Form-C contact outputs, normally energized or de-energized operation, selectable
  • Applications: RCMA423

    • Ground fault detection in grounded and high-resistance AC/DC systems
    • Branch monitoring
    • Variable frequency drives (VFDs)
    • Batteries and battery backup systems
    • Motors and motor control systems
    • Generators, portable and fixed
    • Alarm systems, safety devices
    • General industrial systems
    • Controls and control systems
    • Heat tracing systems
  • Ordering information: RCMA423

    NameResponse Value0...400 μA analog output0(4)...20 mA analog output0...10 V analog outputSPDT contact outputSupply VoltageOrdering Number
    RCMA423-D-130 - 3000 mA 2AC 16 - 72 V (42 - 460 Hz) DC 9.6 - 94 V B94043023
    RCMA423-D-230 - 3000 mA 2AC 70 - 300 V (42 - 460 Hz) DC 70 - 300 V B94043025
  • Downloads: RCMA423

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    RCMA423
    English 04.2013
    Download
    Installation Bulletin
    RCMA423
    English 09.2011
    Download
    Menu Overview / Settings Checklist
    RCMA423
    English 08.2013
    Download
    User Manual
    RCMA423
    English 06.2012
    Download
    Brochure
    Overview of Products
    English 02.2014
    Download
    3D STEP Drawing
    420 Series (Connector Terminals)
    N/A 06.2013
    Download
  • Accessories: RCMA423

    AC/DC Current Transformers

    Current transformers for RCMA420, RCMA423, and RCMS series ground fault monitors (AC/DC systems)

    NameOrdering Number
    W20ABB98080008
    W35ABB98080016
    W60ABB98080016
    W120ABB98080041
    W210ABB98080040
    Connector Cables

    Connector cables for RCMA and RCMS series ground fault monitors

    NameOrdering Number
    WX-100B511100033
    WX-250B511100032
    WX-500B511100031
    WX-1000B511100034
  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • RCMS460

    Multi-channel, digital ground fault monitor for grounded and high-resistance grounded AC/DC systems

    This devices meets or exceeds compliance with the upcoming 2014 NEC 250.167(B) code for ground fault detection on grounded DC systems.

    The RCMS460 monitors for ground faults in grounded and high-resistance grounded AC/DC systems, both single- and three-phase. The RCMS460 is capable of monitoring up to twelve separate systems or branches from one device. Each channel may be set to a separate alarm value. AC circuits may be set to an alarm value of 6 mA to 20 A. DC and mixed AC/DC circuits may be set to an alarm value of 10 mA to 10 A. One DPDT contact output for the device may be set to normally energized or normally de-energized operation, latching or non-latching.

    The detailed LCD display is capable of showing a detailed analysis of the system, including: a chart showing each channel's ground fault current in real-time; individual alarm messages for each channel; and an easy-to-use menu for settings.

    The RCMS460 features three separate time delays - a response delay (0 - 999 s), a startup delay (0 - 99 s), and a delay on release (0 - 999 s). Additional features include a harmonics analysis chart, selectable filtering options, and compatibility with BENDER's gateway devices for connecting to Ethernet and Modbus/TCP networks.

  • Key Features: RCMS460

    • Ground fault monitoring for grounded and high-resistance grounded AC/DC systems
    • Up to 12 separate channels / circuits monitored by one device
    • Detailed digital display showing values in real-time for all channels
    • Adjustable response value ranges, as high as 20 A and as low as 6 mA
    • Many different current transformer sizes available
    • Built-in test and reset button
    • Connections for external test and reset
    • Adjustable time delay, individually adjustable for each channel
    • Latching or non-latching operation, selectable
    • Harmonics analysis
    • Selectable filtering options
    • 1 DPDT Form-C contact output, normally energized or de-energized operation, selectable
    • Compatible with BENDER's advanced communication system
  • Applications: RCMS460

    • Ground fault detection in grounded and high-resistance AC/DC systems
    • Pure DC systems, mixed AC/DC systems
    • Systems with variable frequency drives (VFDs)
    • Motors and motor control systems
    • Power distribution systems
    • Alarm systems, safety devices
    • General industrial systems
    • Controls and control systems
    • Heat tracing systems
  • Ordering information: RCMS460

    NameSupply VoltageOrdering Number
    RCMS460-D-1AC 16 - 72 V (42 - 460 Hz) DC 16 - 94 V B94053001
    RCMS460-D-2AC 70 - 276 V (42 - 460 Hz) DC 70 - 276 V B94053002
  • Downloads: RCMS460

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    RCMS Series
    English 11.2012
    Download
    Installation Bulletin
    RCMS Series
    English 10.2012
    Download
    User Manual
    RCMS Series
    English 03.2012
    Download
    Brochure
    Overview of Products
    English 02.2014
    Download
    3D STEP Drawing
    460 Series
    N/A 06.2013
    Download
  • Accessories: RCMS460

    Remote Communication Systems

    Ethernet and Modbus/TCP communication gateway for BENDER devices

    NameOrdering Number
    COM460IPB95061010
    COM461MTB95061021
    COM462RTUB95061022
    AC Current Transformers

    Current transformers for RCM and RCMS series ground fault monitors (AC only systems)

    NameOrdering Number
    W0-S20B911787
    W1-S35B911731
    W2-S70B911732
    W3-S105B911733
    W4-S140B911734
    W5-S210B911735
    AC/DC Current Transformers

    Current transformers for RCMA420, RCMA423, and RCMS series ground fault monitors (AC/DC systems)

    NameOrdering Number
    W20ABB98080008
    W35ABB98080016
    W60ABB98080016
    W120ABB98080041
    W210ABB98080040
    Rectangular AC Current Transformers

    Rectangular current transformers for RCM and RCMS series ground fault monitors (AC only systems)

    NameOrdering Number
    WR70x175B98080609
    WR115x305B98080610
    Split-Core AC Current Transformers

    Split-core current transformers for RCM and RCMS series ground fault monitors (AC only systems)

    NameOrdering Number
    WS20x30B98080601
    WS50x80B98080603
    WS80x120B98080606
    Flexible AC Current Transformers

    Flexible split-core current transformers for RCM and RCMS series ground fault monitors (AC only systems)

    NameOrdering Number
    WF170-1B98080201
    WF170-2B98080202
    WF250-1B98080203
    WF250-2B98080204
    WF500-1B98080205
    WF500-2B98080206
    WF800-1B98080207
    WF800-2B98080208
    WF1200-1B98080209
    WF1200-2B98080210
    Power Supplies

    Power supply for "AB" type current transformers

    NameOrdering Number
    AN420-2B94053100
    Connector Cables

    Connector cables for RCMA and RCMS series ground fault monitors

    NameOrdering Number
    WXS-100B511100028
    WXS-250B511100029
    WXS-500B511100030
    WXS-1000B511100027
    WXS-1500B511100035
  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • RCMS490

    Multi-channel, digital ground fault monitor for grounded and high-resistance grounded AC/DC systems

    This devices meets or exceeds compliance with the upcoming 2014 NEC 250.167(B) code for ground fault detection on grounded DC systems.

    The RCMS490 monitors for ground faults in grounded and high-resistance grounded AC/DC systems, both single- and three-phase. The RCMS460 is capable of monitoring up to twelve separate systems or branches from one device. Each channel may be set to a separate alarm value. AC circuits may be set to an alarm value of 6 mA to 20 A. DC and mixed AC/DC circuits may be set to an alarm value of 10 mA to 10 A. One DPDT contact output for the device may be set to normally energized or normally de-energized operation, latching or non-latching. The RCMS490 also features 12 separate SPST relay outputs, one for each channel.

    The detailed LCD display is capable of showing a detailed analysis of the system, including: a chart showing each channel's ground fault current in real-time; individual alarm messages for each channel; and an easy-to-use menu for settings.

    The RCMS460 features three separate time delays - a response delay (0 - 999 s), a startup delay (0 - 99 s), and a delay on release (0 - 999 s). Additional features include a harmonics analysis chart, selectable filtering options, and compatibility with BENDER's gateway devices for connecting to Ethernet and Modbus/TCP networks.

  • Key Features: RCMS490

    • Ground fault monitoring for grounded and high-resistance grounded AC/DC systems
    • Up to 12 separate channels / circuits monitored by one device
    • Detailed digital display showing values in real-time for all channels
    • Adjustable response value ranges, as high as 20 A and as low as 6 mA
    • Many different current transformer sizes available
    • Built-in test and reset button
    • Connections for external test and reset
    • Adjustable time delay, individually adjustable for each channel
    • Latching or non-latching operation, selectable
    • Harmonics analysis
    • Selectable filtering options
    • 1 DPDT Form-C contact output, normally energized or de-energized operation, selectable
    • 12 SPST contact outputs, one for each channel (N/O or N/C, selectable)
    • Compatible with BENDER's advanced communication system
  • Applications: RCMS490

    • Ground fault detection in grounded and high-resistance AC/DC systems
    • Pure DC systems, mixed AC/DC systems
    • Systems with variable frequency drives (VFDs)
    • Motors and motor control systems
    • Power distribution systems
    • Alarm systems, safety devices
    • General industrial systems
    • Controls and control systems
    • Heat tracing systems
  • Ordering information: RCMS490

    NameSupply VoltageOrdering Number
    RCMS490-D-1AC 16 - 72 V (42 - 460 Hz) DC 16 - 94 V B94053005
    RCMS490-D-2AC 70 - 276 V (42 - 460 Hz) DC 70 - 276 V B94053006
  • Downloads: RCMS490

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    RCMS Series
    English 11.2012
    Download
    Installation Bulletin
    RCMS Series
    English 10.2012
    Download
    User Manual
    RCMS Series
    English 03.2012
    Download
    Brochure
    Overview of Products
    English 02.2014
    Download
  • Accessories: RCMS490

    Remote Communication Systems

    Ethernet and Modbus/TCP communication gateway for BENDER devices

    NameOrdering Number
    COM460IPB95061010
    COM461MTB95061021
    COM462RTUB95061022
    AC Current Transformers

    Current transformers for RCM and RCMS series ground fault monitors (AC only systems)

    NameOrdering Number
    W0-S20B911787
    W1-S35B911731
    W2-S70B911732
    W3-S105B911733
    W4-S140B911734
    W5-S210B911735
    AC/DC Current Transformers

    Current transformers for RCMA420, RCMA423, and RCMS series ground fault monitors (AC/DC systems)

    NameOrdering Number
    W20ABB98080008
    W35ABB98080016
    W60ABB98080016
    W120ABB98080041
    W210ABB98080040
    Rectangular AC Current Transformers

    Rectangular current transformers for RCM and RCMS series ground fault monitors (AC only systems)

    NameOrdering Number
    WR70x175B98080609
    WR115x305B98080610
    Split-Core AC Current Transformers

    Split-core current transformers for RCM and RCMS series ground fault monitors (AC only systems)

    NameOrdering Number
    WS20x30B98080601
    WS50x80B98080603
    WS80x120B98080606
    Flexible AC Current Transformers

    Flexible split-core current transformers for RCM and RCMS series ground fault monitors (AC only systems)

    NameOrdering Number
    WF170-1B98080201
    WF170-2B98080202
    WF250-1B98080203
    WF250-2B98080204
    WF500-1B98080205
    WF500-2B98080206
    WF800-1B98080207
    WF800-2B98080208
    WF1200-1B98080209
    WF1200-2B98080210
    Power Supplies

    Power supply for "AB" type current transformers

    NameOrdering Number
    AN420-2B94053100
    Connector Cables

    Connector cables for RCMA and RCMS series ground fault monitors

    NameOrdering Number
    WXS-100B511100028
    WXS-250B511100029
    WXS-500B511100030
    WXS-1000B511100027
    WXS-1500B511100035
  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • RCMB101

    CCID-20 for level 2 EV chargers

    The RCMB101 is a small, PCB-style form factor CCID-20 ground fault monitor which detects both AC and DC ground faults. It is designed to be integrated into level 1 and level 2 electric vehicle charging stations. The RCMB101 is UL recognized under UL2231-2.

  • Key Features: RCMB101

    • CCID-20 for level 2 electric vehicle chargers
    • UL 2231 recognized component
    • Detects both AC and DC faults
    • Measuring range up to 20 mA
    • True RMS reading
    • Fixed undervoltage value selectable up to 500 V customizable at factory
    • Frequency range of 0 (DC) to 500 Hz
    • Analog voltage output
    • CT connection monitoring
    • PCB style device, very small footprint and lightweight
  • Applications: RCMB101

    • Grounded AC/DC systems
    • Level 2 electric vehicle chargers
  • Ordering information: RCMB101

    NameResponse ValueOrdering Number
    RCMB1010 - 20 mA B94042098
  • Downloads: RCMB101

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    RCMB101
    English 11.2011
    Download
  • Accessories: RCMB101

  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • RCMB-500 Series

    Integratable ground fault monitoring modules for converters and combiner boxes

    RCMB20-500 and RCMB35-500 series ground fault monitoring modules are designed for fault current monitoring in AC/DC systems. All monitoring electronics are built into the measuring current transformer, no external monitor is required. The small form-factor devices are designed for integration into equipment and panels on the line side, such as frequency converters, inverters, and combiner boxes. Push-wire terminal connectors and insulated wire ensure simple installation and integration.

    RCMB20-500 models feature a 0.78" (20 mm) opening, and RCMB35-500 models feature a 1.38" (35 mm) opening. Both models have a 4 - 20 mA output, proportional to the RMS value of the measured ground fault current from 0 to 500 mA.

  • Key Features: RCMB-500 Series

    • Integratable device for AC/DC fault current monitoring
    • RMS value measurement (AC + DC)
    • 0-500 Hz frequency range
    • Measuring electronics integrated into current transformer
    • 0.78" (20 mm) and 1.38" (35 mm) openings for system conductors
    • 500 mA measuring range
    • 24 VDC supply voltage
    • 4-20 mA analog output
    • CT connection monitoring utilizing cyclical test current
    • Multicolor LED for device status
  • Applications: RCMB-500 Series

    • AC/DC ground fault monitoring
    • Integration into frequency converters / inverters / VFDs
    • Integration into combiner boxes in PV systems
  • Ordering information: RCMB-500 Series

    NameResponse ValueInput currentDiameter of openingSupply VoltageOrdering Number
    RCMB20-500-010 - 500 mA 4... 20 mA0.75" (20 mm)DC 20.4 - 28.8 V B94042101
    RCMB35-500-010 - 500 mA 4... 20 mA1.35" (35 mm)DC 20.4 - 28.8 V B94042102
  • Downloads: RCMB-500 Series

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    RCMB20-500 / RCMB35-500
    English 10.2012
    Download
    Installation Bulletin
    RCMB20-500 / RCMB35-500
    English 10.2012
    Download
    Brochure
    Overview of Products
    English 02.2014
    Download
    Brochure
    Ground Fault Protection in PV Systems
    English 03.2014
    Download
  • Accessories: RCMB-500 Series

  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • RCMA278P-S

    AC/DC Ground fault monitoring module for integration into PV inverters

    The RCMA278P-S is a small, PCB-style form factor AC/DC ground fault monitoring module which detects both AC and DC ground faults. It is designed specifically for integration into PV inverters 10 kW or less.

  • Key Features: RCMA278P-S

    • Designed for integration into PV inverters 10 kW or less
    • Detects both AC and DC ground fault current
    • RMS measurement (AC + DC)
    • 0 - 100 mA measurement range
    • Frequency range of 0 (DC) to 500 Hz
    • Analog voltage output
    • CT connection monitoring
    • PCB style device, very small footprint and lightweight
  • Applications: RCMA278P-S

    • AC/DC systems
    • PV inverters 10 kW or less
  • Ordering information: RCMA278P-S

    NameResponse ValueOrdering Number
    RCMA278P-S0 - 100 mA B94042121
  • Downloads: RCMA278P-S

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    RCMA278P-S
    English 10.2012
    Download
    Brochure
    Ground Fault Protection in PV Systems
    English 03.2014
    Download
  • Accessories: RCMA278P-S

  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • MarinaGuard

    Ground fault monitor panel for marina shore power

    MarinaGuard series panels detect ground faults for shore power in marinas. Options are available for monitoring either main feeders or branch circuits. The MarinaGuard satisfies the new requirements in the 2011 National Electrical Code, article 555.3, "Ground-Fault Protection." All models may be set to 100 mA for feeder protection, and may be set lower if desired. Models for monitoring branch circuits may be steplessly adjustable down to 6 mA. All models feature a NEMA 4X rated enclosure, with test and reset buttons, power and alarm LEDs, and a strobe light on the top of the enclosure for clear indication if a fault has occured.

    All models support the optional "C" add-on, which adds wireless SMS / text messaging of alarms in the MarinaGuard panel. Messages may be sent to multiple technicians. Additionally, MG-S and MG-T models support connecting to BENDER's advanced communication system, to connect to Ethernet and Modbus/TCP networks for remote notification to master stations.

  • Key Features: MarinaGuard

    • Satisfies requirements of NEC article 555.3, "Ground-Fault Protection"
    • Ground fault monitoring for marinas
    • Options for single feeder monitoring and branch monitoring
    • Preset to 100 mA trip level for feeders
    • Steplessly adjustable down to 10 mA for feeder protection, 6 mA for branch protection
    • TEST and REST pushbuttons on front
    • POWER and TRIPPED LEDs on front
    • Strobe light for easily visible alarm indication
    • Contact outputs for notification to harbor master or connection to feeder shunt trip
    • NEMA 4X rated, lockable enclosure
    • Many different current transformer sizes available
    • Optional SMS alarm messaging add-on
    • Branch monitoring version compatible with BENDER's Ethernet and Modbus/TCP communication system
  • Applications: MarinaGuard

    • Ground fault detection in grounded and high-resistance AC systems
    • Marinas, docks, and shore power
  • Ordering information: MarinaGuard

    NameResponse ValueFeeder / Branch Qty.Strobe LightSMS Alarm MessagingContact OutputsOrdering Number
    MG-110 - 10000 mA 11 individualB541300192
    MG-210 - 10000 mA 22 individualMG2
    MG-310 - 10000 mA 33 individualB541300121
    MG-S6 - 20000 mA 121 commonB541300165
    MG-T6 - 20000 mA 121 common, 12 individualB541300253
    MG-1C10 - 10000 mA 11 individualMG1C
    MG-2C10 - 10000 mA 22 individualMG2C
    MG-3C10 - 10000 mA 33 individualMG3C
    MG-SC6 - 20000 mA 121 commonMGSC
    MG-TC6 - 20000 mA 121 common, 12 individualMGTC
  • Downloads: MarinaGuard

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    MarinaGuard Series
    English 03.2013
    Download
    User Manual
    MarinaGuard Series
    English 03.2013
    Download
  • Accessories: MarinaGuard

    Remote Communication Systems

    Ethernet and Modbus/TCP communication gateway for BENDER devices

    NameOrdering Number
    COM460IPB95061010
    COM461MTB95061021
    COM462RTUB95061022
    AC Current Transformers

    Current transformers for RCM and RCMS series ground fault monitors (AC only systems)

    NameOrdering Number
    W0-S20B911787
    W1-S35B911731
    W2-S70B911732
    W3-S105B911733
    W4-S140B911734
    W5-S210B911735
  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • GFGC Series

    Ground fault and ground continuity panel for universal voltages up to 600 VAC

    GFGC series panels provide an all-in-one solution for ground fault detection, ground continuity monitoring, and interruption in case of an alarm. Utilizing the latest in technology, the GFGC panels can detect both AC and DC ground fault currents down to 6 mA without the problems associated with high sensitivity nuisance tripping. The panel also verifies ground connection integrity over a widely adjustable range. A built-in unversal voltage selection allows use of the panel on common system voltages from 120 VAC to 600 VAC (see datasheet for available voltage options). Panels rated for 30 A, 60 A, and 100 A of load current are available.

  • Key Features: GFGC Series

    • All-in-one package for ground fault monitoring, ground connection integrity, open ground detection, and interruption of power
    • Universal voltage selection of common voltages from 120 VAC to 600 VAC
    • 6 mA ground fault trip level
    • Inverse time curve for interrupting circuit on a ground fault
    • Open ground detection
    • Adjustable ground integrity alarm point between 0.1 Ω to 100 Ω
    • NEMA 4/12 rated enclosure
    • External test and reset buttons
    • External LED indication for power and ground fault / ground continuity alarms
    • Internal real-time indications of ground fault current and ground integrity via digital displays
  • Applications: GFGC Series

    • Ground fault detection in grounded systems
    • Ground continuity monitoring
    • Loading docks
    • Fueling stations
    • Systems requiring frequent user connections / disconnections
  • Ordering information: GFGC Series

    NameOrdering Number
    GFGC-30B541300044
    GFGC-60B541300045
    GFGC-100B541300046
  • Downloads: GFGC Series

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    GFGC Series
    English 03.2010
    Download
  • Accessories: GFGC Series