Ground Fault Products for Ungrounded Systems

Installed Ground Fault Location for Ungrounded Systems

BENDER utilizes the latest technology to provide a complete solution for locating faults in ungrounded systems. When combined with our special ground detector, EDS series devices can locate a fault down to the load level. All ground fault location is done while the system remains online, providing a high level of system reliability and availability. The entire ground fault detection and location process can be automated to simplify notification of personnel in the event of a fault.

Installed EDS series modules provide an automated process of detecting faults. Each device can monitor up to twelve separate branches in parallel for any detected ground faults. Simple indication is provided to personnel when a fault is located.

Learn more about BENDER's ground fault location system by viewing the knowledgebase articles to the left.

  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • EDS460 Series

    Ground fault location module for ungrounded AC/DC systems

    The EDS460 ground fault location module, in combination with the IRDH575 ground fault detector, locates branch faults in ungrounded AC/DC systems. Up to 12 separate branches may be monitored by one EDS460 device. Up to 90 EDS devices may be connected together, for a total of 1080 branches simultaneously monitored. The EDS460 works on both AC and DC systems, including systems with variable frequency drives (VFDs). Devices are interconnected via RS-485 to automate the process of locating faults. An LCD display shows which branch has the ground fault after it has been located. One common DPDT contact is built into the EDS460.

    The EDS460 is used with the IRDH575 ground detector and is designed for large power distribution networks. It features a common DPDT contact output.

  • Key Features: EDS460 Series

    • Ground fault location in ungrounded AC/DC systems, when combined with IRDH575 ground detector
    • Up to 12 separate branches monitored from one device
    • All channels scanned in parallel
    • Works on pure AC, pure DC, and mixed AC/DC systems, including systems with variable frequency drives (VFDs)
    • Digital display showing readings in real-time
    • Easy-to-use, onboard menu for managing settings
    • Devices linked via RS-485 display alarm values across all interconnected devices
    • Automatic ground fault detection and location with IRDH575 via RS-485
    • Automatic self-test
    • Built-in test and reset buttons
    • Connections for external test and reset
    • Latching or non-latching operation, selectable
    • One common DPDT contact outputs, normally energized or normally de-energized operation
    • History memory storing up to 300 timestamped events in non-volatile memory
  • Applications: EDS460 Series

    • AC systems, single- and three-phase
    • Pure DC and mixed AC/DC systems
    • Distribution systems requiring fast ground fault location
    • UPS systems and battery systems
    • Systems with variable frequency drives (VFDs)
    • Systems with power conversion components, including rectifiers and inverters
    • Large industrial systems
    • Ungrounded systems with high leakage capacitances
  • Ordering information: EDS460 Series

    NameResponse ValueDisplay typeSupply VoltageOrdering Number
    EDS460-D-12...10 mA DigitalAC 16...72 V (42...460 Hz) DC 16...94 V B91080001
    EDS460-D-22...10 mA DigitalAC 70...276 V (42...460 Hz) DC 70...276 V B91080002
    EDS460-L-12...10 mA AnalogAC 16...72 V (42...460 Hz) DC 16...94 V B91080003
    EDS460-L-22...10 mA AnalogAC 70...276 V (42...460 Hz) DC 70...276 V B91080004
  • Downloads: EDS460 Series

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    EDS460 / EDS490 Series
    English 03.2011
    Download
    Installation Bulletin
    EDS460 / EDS490 Series
    English 10.2011
    Download
    User Manual
    EDS460 / EDS490 Series
    English 03.2011
    Download
    Brochure
    Overview of Products
    English 02.2014
    Download
    3D STEP Drawing
    460 Series
    N/A 06.2013
    Download
  • Accessories: EDS460 Series

    Ground Fault Detectors

    Digital ground fault detector and ground fault location controller for ungrounded AC/DC systems

    NameOrdering Number
    IRDH575B1-435B91065500
    IRDH575B1-427B91065502
    Remote Communication Systems

    Ethernet and Modbus/TCP communication gateway for BENDER devices

    NameOrdering Number
    COM460IPB95061010
    COM461MTB95061021
    COM462RTUB95061022
    AC Current Transformers

    Current transformers for RCM and RCMS series ground fault monitors (AC only systems)

    NameOrdering Number
    W0-S20B911787
    W1-S35B911731
    W2-S70B911732
    W3-S105B911733
    W4-S140B911734
    W5-S210B911735
    Rectangular AC Current Transformers

    Rectangular current transformers for RCM and RCMS series ground fault monitors (AC only systems)

    NameOrdering Number
    WR70x175B98080609
    WR115x305B98080610
    Split-Core AC Current Transformers

    Split-core current transformers for RCM and RCMS series ground fault monitors (AC only systems)

    NameOrdering Number
    WS20x30B98080601
    WS50x80B98080603
    WS80x120B98080606
  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • EDS490 Series

    Ground fault location module for ungrounded AC/DC systems

    The EDS490 ground fault location module, in combination with the IRDH575 ground fault detector, locates branch faults in ungrounded AC/DC systems. Up to 12 separate branches may be monitored by one EDS490 device. Up to 90 EDS devices may be connected together, for a total of 1080 branches simultaneously monitored. The EDS490 works on both AC and DC systems, including systems with variable frequency drives (VFDs). Devices are interconnected via RS-485 to automate the process of locating faults. An LCD display shows which branch has the ground fault after it has been located. One common DPDT contact is built into the EDS490, along with twelve separate SPST contacts, one for each channel.

    The EDS490 is used with the IRDH575 ground detector and is designed for large power distribution networks. It features a common DPDT contact output and twelve SPST contact outputs, one for each channel.

  • Key Features: EDS490 Series

    • Ground fault location in ungrounded AC/DC systems, when combined with IRDH575 ground detector
    • Up to 12 separate branches monitored from one device
    • All channels scanned in parallel
    • Works on pure AC, pure DC, and mixed AC/DC systems, including systems with variable frequency drives (VFDs)
    • Digital display showing readings in real-time
    • Easy-to-use, onboard menu for managing settings
    • Devices linked via RS-485 display alarm values across all interconnected devices
    • Automatic ground fault detection and location with IRDH575 via RS-485
    • Automatic self-test
    • Built-in test and reset buttons
    • Connections for external test and reset
    • Latching or non-latching operation, selectable
    • One common DPDT contact outputs, normally energized or normally de-energized operation
    • 12 Additional SPST contacts, one for each channel, N/O or N/C
    • History memory storing up to 300 timestamped events in non-volatile memory
  • Applications: EDS490 Series

    • AC systems, single- and three-phase
    • Pure DC and mixed AC/DC systems
    • Distribution systems requiring fast ground fault location
    • UPS systems and battery systems
    • Systems with variable frequency drives (VFDs)
    • Systems with power conversion components, including rectifiers and inverters
    • Large industrial systems
    • Ungrounded systems with high leakage capacitances
  • Ordering information: EDS490 Series

    NameResponse ValueDisplay typeSupply VoltageOrdering Number
    EDS490-D-12...10 mA DigitalAC 16...72 V (42...460 Hz) DC 16...94 V B91080009
    EDS490-D-22...10 mA DigitalAC 70...276 V (42...460 Hz) DC 70...276 V B91080010
    EDS490-L-12...10 mA AnalogAC 16...72 V (42...460 Hz) DC 16...94 V B91080011
    EDS490-L-22...10 mA AnalogAC 70...276 V (42...460 Hz) DC 70...276 V B91080012
  • Downloads: EDS490 Series

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    EDS460 / EDS490 Series
    English 03.2011
    Download
    Installation Bulletin
    EDS460 / EDS490 Series
    English 10.2011
    Download
    User Manual
    EDS460 / EDS490 Series
    English 03.2011
    Download
    Brochure
    Overview of Products
    English 02.2014
    Download
  • Accessories: EDS490 Series

    Remote Communication Systems

    Ethernet and Modbus/TCP communication gateway for BENDER devices

    NameOrdering Number
    COM460IPB95061010
    COM461MTB95061021
    COM462RTUB95061022
    AC Current Transformers

    Current transformers for RCM and RCMS series ground fault monitors (AC only systems)

    NameOrdering Number
    W0-S20B911787
    W1-S35B911731
    W2-S70B911732
    W3-S105B911733
    W4-S140B911734
    W5-S210B911735
    Rectangular AC Current Transformers

    Rectangular current transformers for RCM and RCMS series ground fault monitors (AC only systems)

    NameOrdering Number
    WR70x175B98080609
    WR115x305B98080610
    Split-Core AC Current Transformers

    Split-core current transformers for RCM and RCMS series ground fault monitors (AC only systems)

    NameOrdering Number
    WS20x30B98080601
    WS50x80B98080603
    WS80x120B98080606
  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • EDS461 Series

    Ground fault location module for small ungrounded AC/DC systems

    The EDS461 ground fault location module, in combination with the appropriate ground fault detector, locates branch faults in ungrounded AC/DC systems. Up to 12 separate branches may be monitored by one EDS461 device. Up to 90 EDS devices may be connected together, for a total of 1080 branches simultaneously monitored. The EDS461 works on both AC and DC systems, including systems with variable frequency drives (VFDs). Devices are interconnected via RS-485 to automate the process of locating faults. An LCD display shows which branch has the ground fault after it has been located. One common DPDT contact is built into the EDS460.

    The EDS461 is used with the IRDH575 ground detector or LIM2010 line isolation monitor, and is designed for small control networks or isolated power systems. It features a common DPDT contact output.

  • Key Features: EDS461 Series

    • Ground fault location in ungrounded AC/DC systems, when combined with IRDH575 ground detector or LIM2010 line isolation monitor
    • Up to 12 separate branches monitored from one device
    • All channels scanned in parallel
    • Works on pure AC, pure DC, and mixed AC/DC systems, including systems with variable frequency drives (VFDs)
    • Digital display showing readings in real-time
    • Easy-to-use, onboard menu for managing settings
    • Devices linked via RS-485 display alarm values across all interconnected devices
    • Automatic ground fault detection and location with IRDH575 / LIM2010 via RS-485
    • Automatic self-test
    • Built-in test and reset buttons
    • Connections for external test and reset
    • Latching or non-latching operation, selectable
    • One common DPDT contact outputs, normally energized or normally de-energized operation
    • History memory storing up to 300 timestamped events in non-volatile memory
  • Applications: EDS461 Series

    • AC systems, single- and three-phase
    • Pure DC and mixed AC/DC systems
    • Distribution systems requiring fast ground fault location
    • UPS systems and battery systems
    • Systems with variable frequency drives (VFDs)
    • Control networks and small distribution systems
    • Isolated power systems for healthcare facilities
  • Ordering information: EDS461 Series

    NameResponse ValueDisplay typeSupply VoltageOrdering Number
    EDS461-D-10.2...1 mA DigitalAC 16...72 V (42...460 Hz) DC 16...94 V B91080005
    EDS461-D-20.2...1 mA DigitalAC 70...276 V (42...460 Hz) DC 70...276 V B91080006
    EDS461-L-10.2...1 mA AnalogAC 16...72 V (42...460 Hz) DC 16...94 V B91080007
    EDS461-L-20.2...1 mA AnalogAC 70...276 V (42...460 Hz) DC 70...276 V B91080008
  • Downloads: EDS461 Series

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    EDS460 / EDS490 Series
    English 03.2011
    Download
    Installation Bulletin
    EDS460 / EDS490 Series
    English 10.2011
    Download
    User Manual
    EDS460 / EDS490 Series
    English 03.2011
    Download
    Brochure
    Overview of Products
    English 02.2014
    Download
    Brochure
    Isolated Power Systems Equipment
    English 10.2011
    Download
    3D STEP Drawing
    460 Series
    N/A 06.2013
    Download
  • Accessories: EDS461 Series

    AC Current Transformers

    Current transformers for use with EDS461/EDS491 ground fault location modules

    NameOrdering Number
    W20-8000B98080009
    W35-8000B98080017
    W60-8000B98080027
  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • EDS491 Series

    Ground fault location module for small ungrounded AC/DC systems

    The EDS491 ground fault location module, in combination with the appropriate ground fault detector, locates branch faults in ungrounded AC/DC systems. Up to 12 separate branches may be monitored by one EDS491 device. Up to 90 EDS devices may be connected together, for a total of 1080 branches simultaneously monitored. The EDS491 works on both AC and DC systems, including systems with variable frequency drives (VFDs). Devices are interconnected via RS-485 to automate the process of locating faults. An LCD display shows which branch has the ground fault after it has been located. One common DPDT contact is built into the EDS490, along with twelve separate SPST contacts, one for each channel.

    The EDS491 is used with the IRDH575 ground detector or LIM2010 line isolation monitor, and is designed for small control networks or isolated power systems. It features a common DPDT contact output and twelve SPST contact outputs, one for each channel.

  • Key Features: EDS491 Series

    • Ground fault location in ungrounded AC/DC systems, when combined with IRDH575 or LIM2010 ground detector
    • Up to 12 separate branches monitored from one device
    • All channels scanned in parallel
    • Works on pure AC, pure DC, and mixed AC/DC systems, including systems with variable frequency drives (VFDs)
    • Digital display showing readings in real-time
    • Easy-to-use, onboard menu for managing settings
    • Devices linked via RS-485 display alarm values across all interconnected devices
    • Automatic ground fault detection and location with IRDH575 via RS-485
    • Automatic self-test
    • Built-in test and reset buttons
    • Connections for external test and reset
    • Latching or non-latching operation, selectable
    • One common DPDT contact outputs, normally energized or normally de-energized operation
    • 12 Additional SPST contacts, one for each channel, N/O or N/C
    • History memory storing up to 300 timestamped events in non-volatile memory
  • Applications: EDS491 Series

    • AC systems, single- and three-phase
    • Pure DC and mixed AC/DC systems
    • Distribution systems requiring fast ground fault location
    • UPS systems and battery systems
    • Systems with variable frequency drives (VFDs)
    • Control networks and small distribution systems
    • Isolated power systems for healthcare facilities
  • Ordering information: EDS491 Series

    NameResponse ValueDisplay typeSupply VoltageOrdering Number
    EDS491-D-10.2...1 mA DigitalAC 16...72 V (42...460 Hz) DC 16...94 V B91080013
    EDS491-D-20.2...1 mA DigitalAC 70...276 V (42...460 Hz) DC 70...276 V B91080014
    EDS491-L-10.2...1 mA AnalogAC 16...72 V (42...460 Hz) DC 16...94 V B91080015
    EDS490-L-20.2...1 mA AnalogAC 70...276 V (42...460 Hz) DC 70...276 V B91080016
  • Downloads: EDS491 Series

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    EDS460 / EDS490 Series
    English 03.2011
    Download
    Installation Bulletin
    EDS460 / EDS490 Series
    English 10.2011
    Download
    User Manual
    EDS460 / EDS490 Series
    English 03.2011
    Download
    Brochure
    Overview of Products
    English 02.2014
    Download
    Brochure
    Isolated Power Systems Equipment
    English 10.2011
    Download
  • Accessories: EDS491 Series

    AC Current Transformers

    Current transformers for use with EDS461/EDS491 ground fault location modules

    NameOrdering Number
    W20-8000B98080009
    W35-8000B98080017
    W60-8000B98080027