Filter Products

Filter these products by:





Clear

Compare Products

Compare up to four of these products side-by-side:



Compare

Knowledgebase

Related reading on these products:

Online Tools

Use these related online tools to help you select the right product.

Ground Fault Products for Grounded and HRG Systems

AC Only Systems

BENDER's RCM series of ground fault monitors provide advanced warning of ground faults without the problems associated with nuisance tripping. RCM series monitors work on single-phase and three-phase AC systems. A wide variety of adjustable trip levels, display types, and outputs are available.

  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • RCM470LY

    Ground fault monitor for grounded and high-resistance grounded AC systems

    The RCM470LY monitors for ground fault current in grounded and high-resistance grounded AC systems, both single-phase and three-phase. The RCM470LY features a steplessly adjustable setpoint from either 6 mA...600 mA or 10 mA...10 A. Display features include power and alarm LEDS, as well as an LED bar graph indicating how close the system is to the alarm value. An adjustable time delay of 0...10 s is available.

    The device may be set to latching or non-latching operation, and features one DPDT alarm relay which may be set to normally energized or normally de-energized operation. An external BENDER current transformer is required for operation.

  • Key Features: RCM470LY

    • Ground fault monitoring for grounded and high-resistance grounded AC systems
    • Adjustable response value ranges, as high as 10 A and as low as 6 mA
    • Many different current transformer sizes available
    • On, alarm, and bar graph LEDs for indicating device status
    • Built-in test and reset button
    • Connections for external test and reset
    • Connection for optional external panel meter
    • Adjustable time delay, 0...10 s
    • Latching or non-latching operation, selectable
    • 1 DPDT Form-C contact output, normally energized or de-energized operation, selectable
  • Applications: RCM470LY

    • Ground fault detection in grounded and high-resistance AC systems
    • Motors and motor control systems
    • Generators, portable and fixed
    • Alarm systems, safety devices
    • General industrial systems
    • Controls and control systems
    • Heat tracing systems
    • Marinas
  • Ordering information: RCM470LY

    NameResponse ValueSupply VoltageOrdering Number
    RCM470LY10...10000 mA AC 230 V (50...400 Hz) B94012017
    RCM470LY-1310...10000 mA AC 90...132 V (50...400 Hz) B94012019
    RCM470LY-13A10...10000 mA AC 90...132 V (50...60 Hz) B94012019A
    RCM470LY-2110...10000 mA DC 9.6...84 V B94012021
    RCM470LY-2310...10000 mA DC 77...286 V B94012024
    RCM470LY-716...600 mA AC 230 V (50...400 Hz) B94012060
    RCM470LY-71136...600 mA AC 90...132 V (50...400 Hz) B94012051
    RCM470LY-71216...600 mA DC 9.6...84 V B94012050
  • Downloads: RCM470LY

    Document Name Document No. Date Download
    Technical Bulletin / Datasheet
    RCM470LY
    NAE1042010 03.2011
    Download
    Installation Bulletin
    RCM470LY
    NAE1048010 10.2012
    Download
    Brochure
    Overview - Protection Relays
    NAE1001450 04.2013
    Download
  • Accessories: RCM470LY

    AC Current Transformers

    Current transformers for RCM and RCMS series ground fault monitors (AC only systems)

    NameOrdering Number
    W0-S20B911787
    W1-S35B911731
    W2-S70B911732
    W3-S105B911733
    W4-S140B911734
    W5-S210B911735
    Rectangular AC Current Transformers

    Rectangular current transformers for RCM and RCMS series ground fault monitors (AC only systems)

    NameOrdering Number
    WR70x175B98080609
    WR115x305B98080610
    Split-Core AC Current Transformers

    Split-core current transformers for RCM and RCMS series ground fault monitors (AC only systems)

    NameOrdering Number
    WS20x30B98080601
    WS50x80B98080603
    WS80x120B98080606
    External Meters

    Analog output meters for BENDER devices

    NameOrdering Number
    7204-4241B986805
    9604-4241B986807
  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • RCM475LY

    Ground fault monitor for grounded and high-resistance grounded AC systems

    The RCM475LY monitors for ground fault current in grounded and high-resistance grounded AC systems, both single-phase and three-phase. The RCM475LY features a steplessly adjustable setpoint from either 6 mA...600 mA or 10 mA...10 A. Display features include power and alarm LEDS, as well as an LED bar graph indicating how close the system is to the alarm value. An adjustable time delay of 0...10 s is available.

    The device may be set to latching or non-latching operation, and features one DPDT alarm relay which may be set to normally energized or normally de-energized operation. The RCM475LY includes a built-in current transformer.

  • Key Features: RCM475LY

    • Ground fault monitoring for grounded and high-resistance grounded AC systems
    • Built-in current transformer
    • Adjustable response value ranges, as high as 10 A and as low as 6 mA
    • On, alarm, and bar graph LEDs for indicating device status
    • Built-in test and reset button
    • Connections for external test and reset
    • Connection for optional external panel meter
    • Adjustable time delay, 0...10 s
    • Latching or non-latching operation, selectable
    • 1 DPDT Form-C contact output, normally energized or de-energized operation, selectable
  • Applications: RCM475LY

    • Ground fault detection in grounded and high-resistance AC systems
    • Branch monitoring
    • Motors and motor control systems
    • Generators, portable and fixed
    • Alarm systems, safety devices
    • General industrial systems
    • Controls and control systems
    • Heat tracing systems
    • Marinas
  • Ordering information: RCM475LY

    NameResponse ValueSupply VoltageOrdering Number
    RCM475LY10...10000 mA AC 230 V (50...60 Hz) B94012018
    RCM475LY-1310...10000 mA AC 90...132 V (50...60 Hz) B94012035
    RCM475LY-2110...10000 mA DC 9.6...84 V B94012073
    RCM475LY-2310...10000 mA DC 77...286 V B94012069
    RCM475LY-716...600 mA AC 230 V (50...60 Hz) B94012052
    RCM475LY-71136...600 mA AC 90...132 V (50...60 Hz) B94012053
    RCM470LY-71216...600 mA DC 9.6...84 V B94012070
  • Downloads: RCM475LY

    Document Name Document No. Date Download
    Technical Bulletin / Datasheet
    RCM475LY
    NAE1042020 03.2011
    Download
    Brochure
    Overview - Protection Relays
    NAE1001450 04.2013
    Download
  • Accessories: RCM475LY

  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • RCM420

    Digital ground fault monitor for grounded and high-resistance grounded AC systems

    The RCM420 monitors for ground fault current in grounded and high-resistance grounded AC systems, both single-phase and three-phase. The RCM420 reads a true RMS value, and displays the read ground fault current in real-time on the built-in digital display. The RCM420 features a steplessly adjustable setpoint from 10 mA to 10 A. Along with the main alarm value, a prewarning alarm, set as a percentage of the main alarm value, may be set.

    All settings for the device are changed via the device's onboard, easy-to-use menu. Three separate time delays may be utilized - a trip delay (0 to 10 s), a startup delay (0 to 10 s), and a delay on release (0 to 99 s). Two SPDT alarm relays may be set to normally energized or normally de-energized operation, and may be set to latching or non-latching operation. An external BENDER current transformer is required for operation.

  • Key Features: RCM420

    • Ground fault monitoring for grounded and high-resistance grounded AC systems
    • True RMS reading
    • Digital display showing ground fault current in real-time
    • Adjustable response value from 10 mA to 10 A
    • Many different current transformer sizes available
    • Built-in test and reset button
    • Connections for external test and reset
    • Optional versions with analog outputs
    • Adjustable time delays for response delay, startup delay, and delay on release
    • Latching or non-latching operation, selectable
    • 2 SPDT Form-C contact outputs, normally energized or de-energized operation, selectable
  • Applications: RCM420

    • Ground fault detection in grounded and high-resistance AC systems
    • Branch monitoring
    • Motors and motor control systems
    • Generators, portable and fixed
    • Alarm systems, safety devices
    • General industrial systems
    • Controls and control systems
    • Heat tracing systems
    • Marinas
  • Ordering information: RCM420

    NameResponse Value0...400 μA analog output0(4)...20 mA analog output0...10 V analog outputSPDT contact outputSupply VoltageOrdering Number
    RCM420-D-110...10000 mA 2AC 16...72 V (42...460 Hz) DC 9.6...94 V B94014001
    RCM420-D-210...10000 mA 2AC 70...300 V (42...460 Hz) DC 70...300 V B94014002
    RCM420-DM-110...10000 mA AC 16...72 V (42...460 Hz) DC 9.6...94 V B94014005
    RCM420-DM-210...10000 mA AC 70...300 V (42...460 Hz) DC 70...300 V B94014010
    RCM420-DM1C-110...10000 mA 1AC 16...72 V (42...460 Hz) DC 9.6...94 V B94014007
    RCM420-DM1C-210...10000 mA 1AC 70...300 V (42...460 Hz) DC 70...300 V B94014012
    RCM420-DM2C-110...10000 mA 1AC 16...72 V (42...460 Hz) DC 9.6...94 V B94014008
    RCM420-DM2C-210...10000 mA 1AC 70...300 V (42...460 Hz) DC 70...300 V B94014013
    RCM420-DM3C-110...10000 mA 1AC 16...72 V (42...460 Hz) DC 9.6...94 V B94014009
    RCM420-DM3C-210...10000 mA 1AC 70...300 V (42...460 Hz) DC 70...300 V B94014014
  • Downloads: RCM420

    Document Name Document No. Date Download
    Technical Bulletin / Datasheet
    RCM420
    NAE1042030 09.2011
    Download
    Installation Bulletin
    RCM420
    NAE1048030 10.2012
    Download
    User Manual
    RCM420
    TGH1410en 03.2012
    Download
    Installation Bulletin
    RCM420-DM
    NAE1048220 10.2012
    Download
    User Manual
    RCM420-DM
    TGH1404en 07.2010
    Download
    Brochure
    Overview - Protection Relays
    NAE1001450 04.2013
    Download
  • Accessories: RCM420

    AC Current Transformers

    Current transformers for RCM and RCMS series ground fault monitors (AC only systems)

    NameOrdering Number
    W0-S20B911787
    W1-S35B911731
    W2-S70B911732
    W3-S105B911733
    W4-S140B911734
    W5-S210B911735
    Rectangular AC Current Transformers

    Rectangular current transformers for RCM and RCMS series ground fault monitors (AC only systems)

    NameOrdering Number
    WR70x175B98080609
    WR115x305B98080610
    Split-Core AC Current Transformers

    Split-core current transformers for RCM and RCMS series ground fault monitors (AC only systems)

    NameOrdering Number
    WS20x30B98080601
    WS50x80B98080603
    WS80x120B98080606