  • IR420-D4

    Digital ground fault detector for ungrounded single-phase AC systems up to 300 V

    This device meets or exceeds the requirements of NEC 250.21(B) and CEC 10-106(2) for ground detectors in ungrounded systems.

    The IR420-D4 monitors for ground faults in ungrounded single-phase AC systems up to 300 V by measuring the system's insulation resistance. A response value may be set in the range of 1 kΩ to 200 kΩ. The digital display shows the read insulation resistance in real time. All settings are also changed from the digital display. Two separate SPDT contact outputs may be set to normally energized or normally deenergized operation.

    The IR420-D4 utilizes an external supply voltage for power, which allows deenergized systems to also be monitored.

  • Key Features: IR420-D4

    • Meets requirements for ground detectors in accordance with NEC 250.21(B) and CEC 10-106(2)
    • Ground fault detection for ungrounded AC systems up to 300 V
    • Two separately adjustable insulation resistance response values, 1 kΩ...200 kΩ
    • Digital display showing readings in real-time
    • Easy-to-use, onboard menu for managing settings
    • Automatic self-test
    • Analog output
    • Built-in test and reset buttons
    • Connections for external test and reset
    • Latching or non-latching operation, selectable
    • Two SPDT contact outputs, normally energized or normally de-energized operation
  • Applications: IR420-D4

    • Single-phase AC systems up to 300 V
    • Control circuits
    • Portable generators
    • General low-voltage, ungrounded circuits
    • Large industrial systems
  • Ordering information: IR420-D4

    NameResponse ValueSupply VoltageOrdering Number
    IR420-D4-11 - 200 kΩ AC 16 - 72 V (42 - 460 Hz) DC 9.6 - 94 V B91016409
    IR420-D4-21 - 200 kΩ AC 70 - 300 V (42 - 460 Hz) DC 70 - 300 V B91016405
  • Downloads: IR420-D4

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    IR420-D4
    English 04.2011
    Download
    Installation Bulletin
    IR420-D4
    English 05.2012
    Download
    User Manual
    IR420-D4
    English 07.2013
    Download
    User Manual
    IR420-D4
    Spanish 07.2013
    Download
    Brochure
    Overview of Products
    English 02.2014
    Download
    3D STEP Drawing
    420 Series (Standard)
    N/A 06.2013
    Download
  • Accessories: IR420-D4

  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • IR425

    Digital ground fault detector for ungrounded single-phase AC and DC systems up to 300 V

    This device meets or exceeds the requirements of NEC 250.21(B) and CEC 10-106(2) for ground detectors in ungrounded AC systems, as well as the upcoming 2014 requirement of NEC 250.167(A) for ungrounded DC systems.

    The IR425 monitors for ground faults in ungrounded single-phase AC and DC systems up to 300 V by measuring the system's insulation resistance. A response value may be set in the range of 1 kΩ to 200 kΩ. The IR425 also works on pure DC systems, and systems utilizing variable frequency drives (VFDs). The digital display shows the read insulation resistance in real time. All settings are also changed from the digital display. Two separate SPDT contact outputs may be set to normally energized or normally deenergized operation.

    The IR420-D4 utilizes an external supply voltage for power, which allows deenergized systems to also be monitored.

  • Key Features: IR425

    • Meets requirements for ground detectors in accordance with NEC 250.21(B) and CEC 10-106(2)
    • Ground fault detection for ungrounded AC/DC systems up to 300 V
    • Two separately adjustable insulation resistance response values, 1 kΩ...200 kΩ
    • Digital display showing readings in real-time
    • Easy-to-use, onboard menu for managing settings
    • Automatic self-test
    • Analog output
    • Built-in test and reset buttons
    • Connections for external test and reset
    • Latching or non-latching operation, selectable
    • Two SPDT contact outputs, normally energized or normally de-energized operation
  • Applications: IR425

    • Single-phase AC/DC systems up to 300 V
    • Systems with variable frequency drives (VFDs)
    • Control circuits
    • Portable generators
    • General low-voltage, ungrounded circuits
    • Large industrial systems
  • Ordering information: IR425

    NameResponse ValueSupply VoltageOrdering Number
    IR425-D4-11 - 200 kΩ AC 16 - 72 V (42 - 460 Hz) DC 9.6 - 94 V B91036403
    IR425-D4-21 - 200 kΩ AC 70 - 300 V (42 - 460 Hz) DC 70 - 300 V B91036402
  • Downloads: IR425

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    IR425
    English 04.2011
    Download
    Installation Bulletin
    IR425
    English 05.2012
    Download
    User Manual
    IR425
    English 07.2013
    Download
    User Manual
    IR425
    Spanish 07.2013
    Download
    Brochure
    Overview of Products
    English 02.2014
    Download
    3D STEP Drawing
    420 Series (Standard)
    N/A 06.2013
    Download
  • Accessories: IR425

  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • IR470LY

    Ground fault detector for ungrounded (floating) AC systems

    This device meets or exceeds the requirements of NEC 250.21(B) and CEC 10-106(2) for ground detectors in ungrounded systems.

    The IR470LY monitors for ground faults in ungrounded (floating) single-phase and three-phase AC systems by monitoring the system's insulation resistance. The device works on systems up to 793 VAC. Optional voltage coupler accessories extend this range up to 7200 VAC.

    Settings for the IR470LY are modified via the onboard DIP switches and potentiometers. The IR470LY utilizes an external supply voltage for power, which allows deenergized systems to also be monitored.

  • Key Features: IR470LY

    • Meets requirements for ground detectors in accordance with NEC 250.21(B) and CEC 10-106(2)
    • Ground fault detection for ungrounded AC systems (0...793 VAC)
    • Optional voltage coupler extends range to 7200 VAC
    • Adjustable insulation response value, 1 kΩ...200 kΩ
    • LED bar graph displaying currently read insulation resistance
    • DIP switches and potentiometers for settings
    • Built-in test and reset buttons
    • Connections for external test and reset
    • Latching or non-latching operation, selectable
    • One DPDT contact output, normally energized or normally de-energized operation
  • Applications: IR470LY

    • AC systems, single- and three-phase
    • General distribution and control systems
    • Motors and motor control centers
    • Generators, portable and fixed
    • Large industrial systems
  • Ordering information: IR470LY

    NameResponse ValueSupply VoltageOrdering Number
    IR470LY-401 - 200 kΩ AC 230 V (50 - 460 Hz) B91048007
    IR470LY-40111 - 200 kΩ AC 24 V (50 - 460 Hz) B91048012
    IR470LY-40121 - 200 kΩ AC 42 V (50 - 460 Hz) B91048002
    IR470LY-40131 - 200 kΩ AC 90 - 132 V (50 - 460 Hz) B91048011
    IR470LY-40151 - 200 kΩ AC 400 V (50 - 460 Hz) B91048008
    IR470LY-40161 - 200 kΩ AC 500 V (50 - 460 Hz) B91048018
    IR470LY-40171 - 200 kΩ AC 690 V (50 - 460 Hz) B91048017
    IR470LY-40181 - 200 kΩ AC 440 V (50 - 460 Hz) B91048024
    IR470LY-40211 - 200 kΩ DC 9.6 - 84 V B91048006
    IR470LY-40231 - 200 kΩ DC 77 - 286 V B91048026
  • Downloads: IR470LY

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    IR470LY
    English 04.2011
    Download
    Installation Bulletin
    IR470LY
    English 10.2012
    Download
    Brochure
    Overview of Products
    English 02.2014
    Download
  • Accessories: IR470LY

    Voltage Couplers

    Voltage coupler for ungrounded AC systems up to 7200 V

    NameOrdering Number
    AGH520SB913033
  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • iso685

    Digital ground fault detector for ungrounded AC/DC systems

    This device meets or exceeds the requirements of NEC 250.21(B) and CEC 10-106(2) for ground detectors in ungrounded AC systems, as well as the 2014 requirement of NEC 250.167(A) for ungrounded DC systems.

    The iso685 is the newest generation of ground fault monitoring for ungrounded AC/DC systems. Encompassing Bender's extensive expertise in ungrounded systems into one device, the iso685 works on virtually all types of systems, with simple installation and preset settings features.

    The iso685 connects to systems up to 690 VAC / 1000 VDC, and is compatible with systems with variable frequency drives (VFD / ASD). Optional voltage couplers extend this voltage range. During initial setup, the iso685 features predefined profiles that tailors the device's settings to your application. The onboard isoGraph feature allows for trending the system's insulation resistance over time - no software required.

    A variety of alarm outputs are available, including dry contacts, analog outputs, audible buzzer, and remote communication options.

  • Key Features: iso685

    • A single solution for monitoring for ground faults in virtually all types of ungrounded systems up to 690 VAC / 1000 VDC (voltage couplers extend this range)
    • Detects ground faults by monitoring the system's insulation resistance, with two separately adjustable alarm values (1 kΩ - 10 MΩ)
    • Works on pure AC, pure DC, and mixed AC/DC systems, including systems with variable frequency drives (VFDs)
    • Incorporates multiple measurement methods to ensure optimal measurement technique for system type
    • Digital display showing readings in real-time
    • Easy-to-use, onboard menu for managing settings
    • Predefined measurement profiles to simplify setup process by system type / application
    • Advanced trending of system isolation via onboard time-based graphing
    • A variety of alarm outputs, including 2 SPDT contacts, analog outputs, and advanced communication options
    • Automatic self-test
    • History memory storing up to 1000 events
    • Meets requirements for ground detectors in accordance with NEC 250.21(B) and CEC 10-106(2)
  • Applications: iso685

    • AC systems, single- and three-phase
    • Pure DC and mixed AC/DC systems
    • General distribution and control systems requiring fast ground fault location
    • UPS systems and battery systems
    • Systems with variable frequency drives (VFDs)
    • Systems with power conversion components, including rectifiers and inverters
    • Large industrial systems
  • Ordering information: iso685

    NameResponse ValueSupply VoltageOrdering Number
    iso685-D1 - 10000 kΩ AC 100 - 240 V (47 - 460 Hz) DC 24 V B91067010
  • Downloads: iso685

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    iso685
    English 10.2014
    Download
    Installation Bulletin
    iso685
    English 10.2014
    Download
    Brochure
    Overview of Products
    English 02.2014
    Download
  • Accessories: iso685

    Voltage Couplers

    Voltage coupler for ungrounded DC systems up to 1760 V

    NameOrdering Number
    AGH150W-4B98018006
    AGH520SB913033
    AGH676S-4B913055
  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • IRDH275

    Digital ground fault detector for ungrounded AC/DC systems

    This device meets or exceeds the requirements of NEC 250.21(B) and CEC 10-106(2) for ground detectors in ungrounded AC systems, as well as the new 2014 requirement of NEC 250.167(A) for ungrounded DC systems.

    The IRDH275 monitors for ground faults in ungrounded single-phase AC, three-phase AC, and DC systems by monitoring the system's insulation resistance. It may be connected to systems of up to 793 VAC / 650 VDC. Voltage coupler accessories extend this range. The AMP Plus measuring principle utilized by the IRDH275 meets the requirements of modern power systems, including pure DC systems, systems with rectifiers, and systems with variable frequency drives (VFDs). In systems with high leakage capacitances, the IRDH275 automatically adapts itself to ensure an accurate reading.

    The IRDH275 features a digital display showing the system's insulation resistance'in real-time. All settings are changed via the device's built-in menu. The IRDH275 utilizes an external supply voltage for power, which allows deenergized systems to also be monitored.

    The IRDH275 is a DIN rail mounted type device. For the panel mounted version, please refer to the IRDH375.

  • Key Features: IRDH275

    • Meets requirements for ground detectors in accordance with NEC 250.21(B) and CEC 10-106(2)
    • Ground fault detection for ungrounded AC/DC systems (0...793 VAC, 0...650 VDC)
    • Optional voltage coupler extends range to 7200 VAC / 1760 VDC
    • Two separately adjustable insulation resistance response values, 1 kΩ...10 MΩ
    • Works on pure AC, pure DC, and mixed AC/DC systems, including systems with variable frequency drives (VFDs)
    • Digital display showing readings in real-time
    • Easy-to-use, onboard menu for managing settings
    • Automatic self-test
    • Analog output
    • Built-in test and reset buttons
    • Connections for external test and reset
    • Latching or non-latching operation, selectable
    • Two SPDT contact outputs, normally energized or normally de-energized operation
    • History memory storing up to 300 events ("B" version)
  • Applications: IRDH275

    • AC systems, single- and three-phase
    • Pure DC and mixed AC/DC systems
    • General distribution and control systems requiring fast ground fault location
    • UPS systems and battery systems
    • Systems with variable frequency drives (VFDs)
    • Systems with power conversion components, including rectifiers and inverters
    • Large industrial systems
  • Ordering information: IRDH275

    NameResponse ValueEnhanced temperature and vibration protectionHistory memory for up to 300 recordsCommunication capability0(4) - 20 mA analog outputSupply VoltageOrdering Number
    IRDH275-4351 - 10000 kΩ AC 88 - 264 V (20 - 460 Hz) DC 77 - 286 V B91065100
    IRDH275-4271 - 10000 kΩ DC 19.2 - 72 V B91065104
    IRDH275-4251 - 10000 kΩ DC 10 - 30 V B91065108
    IRDH275B-4351 - 10000 kΩ AC 88 - 264 V (20 - 460 Hz) DC 77 - 286 V B91065101
    IRDH275B-4271 - 10000 kΩ DC 19.2 - 72 V B91065105
    IRDH275B-4251 - 10000 kΩ DC 10 - 30 V B91065109
    IRDH275BW-4351 - 10000 kΩ AC 88 - 264 V (20 - 460 Hz) DC 77 - 286 V B91065101W
    IRDH275BW-4271 - 10000 kΩ DC 19.2 - 72 V B91065105W
    IRDH275BW-4251 - 10000 kΩ DC 10 - 30 V B91065109W
  • Downloads: IRDH275

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    IRDH275
    English 08.2013
    Download
    Installation Bulletin
    IRDH275
    English 08.2013
    Download
    User Manual
    IRDH275
    English 05.2011
    Download
    Brochure
    Overview of Products
    English 02.2014
    Download
  • Accessories: IRDH275

    Remote Communication Systems

    Ethernet and Modbus/TCP communication gateway for BENDER devices

    NameOrdering Number
    COM460IPB95061010
    COM461MTB95061021
    COM462RTUB95061022
    Voltage Couplers

    Voltage coupler for ungrounded DC systems up to 1760 V

    NameOrdering Number
    AGH150W-4B98018006
    AGH520SB913033
    AGH676S-4B913055
    External Meters

    Analog output meters for BENDER devices

    NameOrdering Number
    7204-1421B986763
    9604-1421B986764
  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • isoPV425

    Digital ground fault detector for ungrounded solar arrays up to 100 kW

    This device meets or exceeds the requirements of NEC 690.35 and CEC 64-018(1)(e) for ground fault detection on ungrounded solar arrays.

    Designed specifically for photovoltaic systems 100 kW and below, the isoPV425 ground fault detector provides early indication of ground faults before leakage current may even be present. The device detects both AC and DC ground faults by monitoring the system's insulation resistance. The isoPV425 and AGH420 can connect to systems up to 690 VAC / 1000 VDC.

    Insulation resistance values are displayed in real-time on the device's LCD display. Additional overvoltage and undervoltage detection are available, with voltage measurements from positive to ground and negative to ground when connected to DC. Two single pole contacts are available, which may be set to normally energized (failsafe) or normally deenergized (non-failsafe) mode. An RS-485 interface is available for connection to remote BENDER communication gateways. For advanced users, separately adjustable values for resistance and impedance are available as well.

    The isoPV425 may also be used for determining PV system isolation prior to startup on both grounded and ungrounded solar arrays, per the upcoming 2014 requirements of NEC 690.5(A)(1) and NEC 690.35(C)(1).

  • Key Features: isoPV425

    • Meets requirements of NEC 690.35 and CEC 64-018(1)(e) for ground fault detection on ungrounded solar arrays
    • Early indication of both AC and DC ground faults on the array side of the isolated system
    • Connects to DC arrays up to 1000 VDC
    • Designed specifically for photovoltaic systems
    • Two separately adjustable insulation resistance response values
    • Additionally provides readings of voltage to ground (+ to GND and - to GND)
    • Additional overvoltage and undervoltage alarms available
    • Works on systems with up to 500 μF
    • Digital display showing readings in real-time
    • Easy-to-use, onboard menu for managing settings
    • Automatic self-test
    • Analog output
    • Built-in test and reset buttons
    • Connections for external test and reset
    • Latching or non-latching operation, selectable
    • Two single pole contact outputs, normally energized or normally de-energized operation
    • Compatibility with BENDER's remote communication system
  • Applications: isoPV425

    • Isolated (ungrounded) solar arrays 100 kW or less
    • AC systems, single- and three-phase
    • Pure DC and mixed AC/DC systems
    • Systems with high leakage capacitances
    • Multiple ungrounded systems connected via tiebreaker / interlock
  • Ordering information: isoPV425

    NameResponse ValueSupply VoltageOrdering Number
    isoPV425-D4 and AGH4201 - 500 kΩ AC 100 - 240 V (41 - 63 Hz) DC 24 - 240 V B91036303
  • Downloads: isoPV425

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    isoPV425 and AGH420
    English 08.2013
    Download
    Menu Overview / Settings Checklist
    isoPV425 and AGH420
    English 08.2013
    Download
    User Manual
    isoPV425 and AGH420
    English 08.2013
    Download
    Brochure
    Ground Fault Protection in PV Systems
    English 03.2014
    Download
  • Accessories: isoPV425

  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • isoPV

    Digital ground fault detector for ungrounded solar arrays

    This device meets or exceeds the requirements of NEC 690.35 and CEC 64-018(1)(e) for ground fault detection on ungrounded solar arrays, as well as the upcoming 2014 requirements for array isolation testing prior to startup.

    The isoPV detects ground faults in isolated (ungrounded) solar arrays up to 793 VAC / 1100 VDC. The iso-PV monitors for ground faults by measuring the system's insulation resistance, providing early indication of ground faults before leakage current may even be present. Both AC and DC ground faults can be detected, including on systems that have high leakage capacitances.

    Designed specifically for photovoltaic arrays, the iso-PV satisfies the ground detection requirements of NEC article 690.35 for ungrounded DC solar arrays. Included are two components, the ground detector and the high voltage coupler. Both are required for operation (the voltage coupler may be installed in a separate cabinet to keep high voltage connections separate). The iso-PV features a digital display which shows the array's insulation resistance in real-time. Two SPDT contacts are available.

    The isoPV may also be used for testing array isolation prior to startup on both grounded and ungrounded arrays, per the upcoming 2014 requirements of NEC 690.5(A)(1) and NEC 690.35(C)(1).

  • Key Features: isoPV

    • Meets requirements of NEC 690.35 and CEC 64-018(1)(e) for ground fault detection on ungrounded solar arrays
    • Early indication of both AC and DC ground faults on the array side of the isolated system
    • Connects to DC arrays up to 1100 VDC
    • Designed specifically for photovoltaic systems
    • Separate voltage coupler gives the flexibility of a separate high voltage cabinet
    • Two separately adjustable insulation resistance response values, 200 Ω...100 kΩ
    • Works on systems with up to 2000 μF
    • Digital display showing readings in real-time
    • Easy-to-use, onboard menu for managing settings
    • Automatic self-test
    • Analog output
    • Built-in test and reset buttons
    • Connections for external test and reset
    • Latching or non-latching operation, selectable
    • Two SPDT contact outputs, normally energized or normally de-energized operation
    • History memory storing up to 300 events
    • Compatibility with BENDER's remote communication system
  • Applications: isoPV

    • Isolated (ungrounded) solar arrays
    • AC systems, single- and three-phase
    • Pure DC and mixed AC/DC systems
    • Systems with high leakage capacitances
    • Multiple ungrounded systems connected via tiebreaker / interlock
  • Ordering information: isoPV

    NameResponse ValueSupply VoltageOrdering Number
    isoPV-335 and AGH-PV0.2 - 100 kΩ AC 88 - 264 V (42 - 460 Hz) DC 77 - 286 V B91065133W
    isoPV-327 and AGH-PV0.2 - 100 kΩ DC 19.2 - 72 V B91065132W
  • Downloads: isoPV

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    isoPV
    English 07.2013
    Download
    Installation Bulletin
    isoPV
    English 10.2012
    Download
    User Manual
    isoPV
    English 06.2012
    Download
    Brochure
    Ground Fault Protection in PV Systems
    English 03.2014
    Download
  • Accessories: isoPV

  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • isoLR275

    Digital ground fault detector for ungrounded, low-resistance systems

    This device meets or exceeds the requirements of NEC 250.21(B) and CEC 10-106(2) for ground detectors in ungrounded AC systems, as well as the upcoming 2014 requirement of NEC 250.167(A) for ungrounded DC systems.

    The isoLR275 detects ground faults in ungrounded, low resistance systems up to 793 VAC / 1100 VDC. The iso-PV monitors for ground faults by measuring the system's insulation resistance, providing early indication of ground faults before leakage current may even be present. Both AC and DC ground faults can be detected, including on systems that have high leakage capacitances.

    The isoLR275 is specifically designed for ungrounded systems which run at a low resistance to ground. Included are two components, the ground detector and the high voltage coupler. Both are required for operation (the voltage coupler may be installed in a separate cabinet to keep high voltage connections separate).

    The isoLR275 features a digital display which shows the system's insulation resistance in real-time. Two SPDT contacts are available. The isoLR275 utilizes an external supply voltage for power.

  • Key Features: isoLR275

    • Meets requirements for ground detectors in accordance with NEC 250.21(B) and CEC 10-106(2)
    • Early indication of both AC and DC ground faults
    • Connects to systems up to 793 VAC / 1100 VDC
    • Designed specifically for systems operating with a low resistance to ground
    • Separate voltage coupler gives the flexibility of a separate high voltage cabinet
    • Two separately adjustable insulation resistance response values, 200 Ω...100 kΩ
    • Works on systems with up to 500 μF
    • Digital display showing readings in real-time
    • Easy-to-use, onboard menu for managing settings
    • Automatic self-test
    • Analog output
    • Built-in test and reset buttons
    • Connections for external test and reset
    • Latching or non-latching operation, selectable
    • Two SPDT contact outputs, normally energized or normally de-energized operation
    • History memory storing up to 300 events
    • Compatibility with BENDER's remote communication system
    • Meets requirements for ground detectors in accordance with NEC 250.21(B) and CEC 10-106(2)
  • Applications: isoLR275

    • AC systems, single- and three-phase
    • Pure DC and mixed AC/DC systems
    • Systems operating with a low resistance to ground
    • General distribution and control systems requiring fast ground fault location
    • UPS systems and battery systems
    • Systems with variable frequency drives (VFDs)
    • Large furnaces / smelters
    • Systems with power conversion components, including rectifiers and inverters
    • Large industrial systems
  • Ordering information: isoLR275

    NameResponse ValueSupply VoltageOrdering Number
    isoLR275-335 and AGH-LR-30.2 - 100 kΩ AC 88 - 264 V (42 - 460 Hz) DC 77 - 286 V B91065703W
    isoLR275-327 and AGH-LR-30.2 - 100 kΩ DC 19.2 - 72 V B91065702W
  • Downloads: isoLR275

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    isoLR275
    English 12.2011
    Download
    Installation Bulletin
    isoLR275
    English 12.2011
    Download
    User Manual
    isoLR275
    English 06.2012
    Download
    Brochure
    Overview of Products
    English 02.2014
    Download
  • Accessories: isoLR275

  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • IRDH375

    Digital ground fault detector for ungrounded AC/DC systems

    This device meets or exceeds the requirements of NEC 250.21(B) and CEC 10-106(2) for ground detectors in ungrounded AC systems, as well as the new 2014 requirement of NEC 250.167(A) for ungrounded DC systems.

    The IRDH375 monitors for ground faults in ungrounded single-phase AC, three-phase AC, and DC systems by monitoring the system's insulation resistance. It may be connected to systems of AC 0...793 V and DC 0...650 V. Optional voltage coupler accessories extend this range. The AMP Plus measuring principle utilized by the IRDH375 meets the requirements of modern power systems, including pure DC systems, systems with rectifiers, and systems with variable frequency drives (VFDs). In systems with high leakage capacitances, the IRDH375 automatically adapts itself to ensure a reliable reading.

    The IRDH375 features a digital display showing the system's insulation resistance in real-time. All settings are changed via the device's built-in menu. The IRDH375 utilizes an external supply voltage for power, which allows deenergized systems to also be monitored.

    The IRDH375 is a panel mounted type device. For the DIN rail mounted version, please refer to the IRDH275.

  • Key Features: IRDH375

    • Meets requirements for ground detectors in accordance with NEC 250.21(B) and CEC 10-106(2)
    • Ground fault detection for ungrounded AC/DC systems (0...793 VAC, 0...650 VDC)
    • Optional voltage coupler extends range to 7200 VAC / 1760 VDC
    • Two separately adjustable insulation resistance response values, 1 kΩ...10 MΩ
    • Works on pure AC, pure DC, and mixed AC/DC systems, including systems with variable frequency drives (VFDs)
    • Digital display showing readings in real-time
    • Easy-to-use, onboard menu for managing settings
    • Automatic self-test
    • Analog output
    • Built-in test and reset buttons
    • Connections for external test and reset
    • Latching or non-latching operation, selectable
    • Two SPDT contact outputs, normally energized or normally de-energized operation
    • History memory storing up to 300 events ("B" version)
  • Applications: IRDH375

    • AC systems, single- and three-phase
    • Pure DC and mixed AC/DC systems
    • UPS systems and battery systems
    • Systems with variable frequency drives (VFDs)
    • Systems with power conversion components, including rectifiers and inverters
    • Large industrial systems
  • Ordering information: IRDH375

    NameResponse ValueEnhanced temperature and vibration protectionHistory memory for up to 300 recordsCommunication capability0(4) - 20 mA analog outputSupply VoltageOrdering Number
    IRDH375-4351 - 10000 kΩ AC 88 - 264 V (20 - 460 Hz) DC 77 - 286 V B91065000
    IRDH375-4271 - 10000 kΩ DC 19.2 - 72 V B91065002
    IRDH375-4251 - 10000 kΩ DC 10 - 30 V B91065001
    IRDH375B-4351 - 10000 kΩ AC 88 - 264 V (20 - 460 Hz) DC 77 - 286 V B91065004
    IRDH375B-4271 - 10000 kΩ DC 19.2 - 72 V B91065006
    IRDH375B-4251 - 10000 kΩ DC 10 - 30 V B91065005
    IRDH375BW-4351 - 10000 kΩ AC 88 - 264 V (20 - 460 Hz) DC 77 - 286 V B91065004W
    IRDH375BW-4271 - 10000 kΩ DC 19.2 - 72 V B91065006W
    IRDH375BW-4251 - 10000 kΩ DC 10 - 30 V B91065005W
  • Downloads: IRDH375

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    IRDH375
    English 08.2013
    Download
    Installation Bulletin
    IRDH375
    English 08.2013
    Download
    User Manual
    IRDH375
    English 05.2011
    Download
    Brochure
    Overview of Products
    English 02.2014
    Download
  • Accessories: IRDH375

    Remote Communication Systems

    Ethernet and Modbus/TCP communication gateway for BENDER devices

    NameOrdering Number
    COM460IPB95061010
    COM461MTB95061021
    COM462RTUB95061022
    Voltage Couplers

    Voltage coupler for ungrounded DC systems up to 1760 V

    NameOrdering Number
    AGH150W-4B98018006
    AGH520SB913033
    AGH676S-4B913055
  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • IRDH575

    Digital ground fault detector and ground fault location controller for ungrounded AC/DC systems

    This device meets or exceeds the requirements of NEC 250.21(B) and CEC 10-106(2) for ground detectors in ungrounded AC systems, as well as the new 2014 requirement of NEC 250.167(A) for ungrounded DC systems.

    The IRDH575 monitors for ground faults in ungrounded single-phase AC, three-phase AC, and DC systems by monitoring the system's insulation resistance. The AMP Plus measuring principle meets the requirements of modern power systems, including pure DC systems, systems with rectifiers, and systems with variable frequency drives (VFDs). Additionally, the IRDH575 works in combination with EDS series devices to create a ground fault location system for ungrounded circuits.

  • Key Features: IRDH575

    • Meets requirements for ground detectors in accordance with NEC 250.21(B) and CEC 10-106(2)
    • Ground fault detection for ungrounded AC/DC systems
    • Ground fault location in ungrounded AC/DC systems with EDS series location device
    • Two separately adjustable insulation resistance response values, 1 kΩ...10 MΩ
    • Works on pure AC, pure DC, and mixed AC/DC systems, including systems with variable frequency drives (VFDs)
    • Digital display showing readings in real-time
    • Easy-to-use, onboard menu for managing settings
    • Simple, automatic ground fault location with EDS device via RS-485
    • Automatic self-test
    • Analog output
    • Built-in test and reset buttons
    • Connections for external test and reset
    • Latching or non-latching operation, selectable
    • Two SPDT contact outputs, normally energized or normally de-energized operation
    • History memory storing up to 300 events
  • Applications: IRDH575

    • AC systems, single- and three-phase
    • Pure DC and mixed AC/DC systems
    • UPS systems and battery systems
    • Systems with variable frequency drives (VFDs)
    • Systems with power conversion components, including rectifiers and inverters
    • Large industrial systems
    • Ungrounded systems with high leakage capacitances
    • Interconnected ungrounded systems
  • Ordering information: IRDH575

    NameResponse ValueSystem VoltageEnhanced temperature and vibration protectionHistory memory for up to 300 recordsCommunication capability0(4) - 20 mA analog outputSupply VoltageOrdering Number
    IRDH575B1-4351 - 10000 kΩ AC 20 - 575 V (50 - 460 Hz) DC 20 - 575 V AC 340 - 760 V (50 - 460 Hz) DC 340 - 575 V AC 88 - 264 V (40 - 460 Hz) DC 77 - 286 V B91065500
    IRDH575B1-4271 - 10000 kΩ AC 20 - 575 V (50 - 460 Hz) DC 20 - 575 V AC 340 - 760 V (50 - 460 Hz) DC 340 - 575 V DC 19.2 - 72 V B91065502
  • Downloads: IRDH575

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    IRDH575
    English 03.2011
    Download
    Installation Bulletin
    IRDH575
    English 10.2011
    Download
    User Manual
    IRDH575
    English 08.2011
    Download
    Brochure
    Overview of Products
    English 02.2014
    Download
  • Accessories: IRDH575

    Ground Fault Location Modules

    Ground fault location module for ungrounded AC/DC systems

    NameOrdering Number
    EDS460-D-1B91080001
    EDS460-D-2B91080002
    EDS460-L-1B91080003
    EDS460-L-2B91080004
    EDS490-D-1B91080009
    EDS490-D-2B91080010
    EDS490-L-1B91080011
    EDS490-L-2B91080012
    EDS461-D-1B91080005
    EDS461-D-2B91080006
    EDS461-L-1B91080007
    EDS461-L-2B91080008
    EDS491-D-1B91080013
    EDS491-D-2B91080014
    EDS491-L-1B91080015
    EDS490-L-2B91080016
    Remote Communication Systems

    Ethernet and Modbus/TCP communication gateway for BENDER devices

    NameOrdering Number
    COM460IPB95061010
    COM461MTB95061021
    COM462RTUB95061022
  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • IR155 10 Series

    Ground fault detector for level 3 electric vehicle chargers (EVSE)

    The IR155 10 series detects ground faults in ungrounded DC electric vehicle chargers (level 3). The device monitors the system's insulation resistance between the charger and ground, for systems up to 800 VDC. The advanced measurement method monitors both the DC side as well as the AC motor side of the system, even through high system interference conditions caused by motor control processes. The devices are PCB-style with a very small footprint and light weight. Various connector options are available.

    Version IR155-3210 is a UL 2231 recognized component for electric vehicle charging stations, and utilizes an automotive rated connector.

  • Key Features: IR155 10 Series

    • Ground detector for ungrounded DC level 3 electric vehicle chargers up to 800 VDC
    • IR155-3210 UL2231 recognized component
    • Detects faults on both the DC side as well as the AC motor side
    • Fixed alarm value of 100 kΩ
    • Fixed response value between 100 kΩ and 200 kΩ customizable at factory
    • Fixed undervoltage value selectable up to 500 V customizable at factory
    • Automatic self-test
    • Go / No-Go output
    • Measurement output of the system's insulation resistance
    • PCB style device, very small footprint and lightweight
  • Applications: IR155 10 Series

    • Ungrounded DC systems
    • Level 3 electric vehicle chargers
  • Ordering information: IR155 10 Series

    NameResponse SpecConnector TypeOrdering Number
    IR155-3210100 kΩ alarm, 300 V undervoltageTyco MICRO MATE-N-LOCK automotive connectorB91068140V4
    IR155-3210Parameters customizable at factoryTyco MICRO MATE-N-LOCK automotive connectorB91068140CV4
    IR155-4210100 kΩ alarm, 300 V undervoltageSamtec / Molex connectorsB91068143
    IR155-4210Parameters customizable at factorySamtec / Molex connectorsB91068143C
  • Downloads: IR155 10 Series

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    IR155 10 Series
    English 01.2013
    Download
    Brochure
    Overview of Products
    English 02.2014
    Download
  • Accessories: IR155 10 Series

  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • IR155 03-04 Series

    Ground fault detector for AC/DC electric vehicles (EV)

    The IR155 03/04 series detects ground faults in ungrounded drive systems in electric vehicles. The device monitors the system's insulation resistance between the charger and ground, for systems up to 1000 VDC. The advanced measurement method monitors both the DC side as well as the AC motor side of the system, even through high system interference conditions caused by motor control processes. The devices are PCB-style with a very small footprint and light weight. Various connector and drive output options are available.

  • Key Features: IR155 03-04 Series

    • Ground detector for ungrounded DC level 3 electric vehicle chargers up to 1000 VDC
    • Detects faults on both the DC side as well as the AC motor side
    • Fixed alarm value of 100 kΩ
    • Fixed response value between 100 kΩ and 1 MΩ customizable at factory
    • Fixed undervoltage value selectable up to 500 V customizable at factory
    • Automatic self-test
    • Go / No-Go output
    • Measurement output of the system's insulation resistance
    • PCB style device, very small footprint and lightweight
  • Applications: IR155 03-04 Series

    • Ungrounded DC systems
    • Integration into electric vehicle drive systems
  • Ordering information: IR155 03-04 Series

    NameResponse SpecOutput TypeConnector TypeOrdering Number
    IR155-3203100 kΩ alarm, 300 V undervoltageLow side driverTyco MICRO MATE-N-LOCK automotive connectorB91068138V4
    IR155-3203100 kΩ alarm, 300 V undervoltageLow side driverTyco MICRO MATE-N-LOCK automotive connectorB91068138CV4
    IR155-4203100 kΩ alarm, 300 V undervoltageLow side driverSamtec / Molex connectorsB91068141
    IR155-4203100 kΩ alarm, 300 V undervoltageLow side driverSamtec / Molex connectorsB91068141C
    IR155-3204100 kΩ alarm, undervoltage inactiveHigh side driverTyco MICRO MATE-N-LOCK automotive connectorB91068139V4
    IR155-3204Parameters customizable at factoryHigh side driverTyco MICRO MATE-N-LOCK automotive connectorB91068139CV4
    IR155-4204100 kΩ alarm, undervoltage inactiveHigh side driverSamtec / Molex connectorsB91068142
    IR155-4204Parameters customizable at factoryHigh side driverSamtec / Molex connectorsB91068142C
  • Downloads: IR155 03-04 Series

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    IR155 03-04 Series
    English 01.2013
    Download
    Brochure
    Overview of Products
    English 02.2014
    Download
  • Accessories: IR155 03-04 Series

  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • EDS460 Series

    Ground fault location module for ungrounded AC/DC systems

    The EDS460 ground fault location module, in combination with the IRDH575 ground fault detector, locates branch faults in ungrounded AC/DC systems. Up to 12 separate branches may be monitored by one EDS460 device. Up to 90 EDS devices may be connected together, for a total of 1080 branches simultaneously monitored. The EDS460 works on both AC and DC systems, including systems with variable frequency drives (VFDs). Devices are interconnected via RS-485 to automate the process of locating faults. An LCD display shows which branch has the ground fault after it has been located. One common DPDT contact is built into the EDS460.

    The EDS460 is used with the IRDH575 ground detector and is designed for large power distribution networks. It features a common DPDT contact output.

  • Key Features: EDS460 Series

    • Ground fault location in ungrounded AC/DC systems, when combined with IRDH575 ground detector
    • Up to 12 separate branches monitored from one device
    • All channels scanned in parallel
    • Works on pure AC, pure DC, and mixed AC/DC systems, including systems with variable frequency drives (VFDs)
    • Digital display showing readings in real-time
    • Easy-to-use, onboard menu for managing settings
    • Devices linked via RS-485 display alarm values across all interconnected devices
    • Automatic ground fault detection and location with IRDH575 via RS-485
    • Automatic self-test
    • Built-in test and reset buttons
    • Connections for external test and reset
    • Latching or non-latching operation, selectable
    • One common DPDT contact outputs, normally energized or normally de-energized operation
    • History memory storing up to 300 timestamped events in non-volatile memory
  • Applications: EDS460 Series

    • AC systems, single- and three-phase
    • Pure DC and mixed AC/DC systems
    • Distribution systems requiring fast ground fault location
    • UPS systems and battery systems
    • Systems with variable frequency drives (VFDs)
    • Systems with power conversion components, including rectifiers and inverters
    • Large industrial systems
    • Ungrounded systems with high leakage capacitances
  • Ordering information: EDS460 Series

    NameResponse ValueDisplay typeSupply VoltageOrdering Number
    EDS460-D-12 - 10 mA DigitalAC 16 - 72 V (42 - 460 Hz) DC 16 - 94 V B91080001
    EDS460-D-22 - 10 mA DigitalAC 70 - 276 V (42 - 460 Hz) DC 70 - 276 V B91080002
    EDS460-L-12 - 10 mA AnalogAC 16 - 72 V (42 - 460 Hz) DC 16 - 94 V B91080003
    EDS460-L-22 - 10 mA AnalogAC 70 - 276 V (42 - 460 Hz) DC 70 - 276 V B91080004
  • Downloads: EDS460 Series

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    EDS460 / EDS490 Series
    English 03.2011
    Download
    Installation Bulletin
    EDS460 / EDS490 Series
    English 10.2011
    Download
    User Manual
    EDS460 / EDS490 Series
    English 03.2011
    Download
    Brochure
    Overview of Products
    English 02.2014
    Download
    3D STEP Drawing
    460 Series
    N/A 06.2013
    Download
  • Accessories: EDS460 Series

    Ground Fault Detectors

    Digital ground fault detector and ground fault location controller for ungrounded AC/DC systems

    NameOrdering Number
    IRDH575B1-435B91065500
    IRDH575B1-427B91065502
    Remote Communication Systems

    Ethernet and Modbus/TCP communication gateway for BENDER devices

    NameOrdering Number
    COM460IPB95061010
    COM461MTB95061021
    COM462RTUB95061022
    AC Current Transformers

    Current transformers for RCM and RCMS series ground fault monitors (AC only systems)

    NameOrdering Number
    W0-S20B911787
    W1-S35B911731
    W2-S70B911732
    W3-S105B911733
    W4-S140B911734
    W5-S210B911735
    Rectangular AC Current Transformers

    Rectangular current transformers for RCM and RCMS series ground fault monitors (AC only systems)

    NameOrdering Number
    WR70x175B98080609
    WR115x305B98080610
    Split-Core AC Current Transformers

    Split-core current transformers for RCM and RCMS series ground fault monitors (AC only systems)

    NameOrdering Number
    WS20x30B98080601
    WS50x80B98080603
    WS80x120B98080606
  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • EDS490 Series

    Ground fault location module for ungrounded AC/DC systems

    The EDS490 ground fault location module, in combination with the IRDH575 ground fault detector, locates branch faults in ungrounded AC/DC systems. Up to 12 separate branches may be monitored by one EDS490 device. Up to 90 EDS devices may be connected together, for a total of 1080 branches simultaneously monitored. The EDS490 works on both AC and DC systems, including systems with variable frequency drives (VFDs). Devices are interconnected via RS-485 to automate the process of locating faults. An LCD display shows which branch has the ground fault after it has been located. One common DPDT contact is built into the EDS490, along with twelve separate SPST contacts, one for each channel.

    The EDS490 is used with the IRDH575 ground detector and is designed for large power distribution networks. It features a common DPDT contact output and twelve SPST contact outputs, one for each channel.

  • Key Features: EDS490 Series

    • Ground fault location in ungrounded AC/DC systems, when combined with IRDH575 ground detector
    • Up to 12 separate branches monitored from one device
    • All channels scanned in parallel
    • Works on pure AC, pure DC, and mixed AC/DC systems, including systems with variable frequency drives (VFDs)
    • Digital display showing readings in real-time
    • Easy-to-use, onboard menu for managing settings
    • Devices linked via RS-485 display alarm values across all interconnected devices
    • Automatic ground fault detection and location with IRDH575 via RS-485
    • Automatic self-test
    • Built-in test and reset buttons
    • Connections for external test and reset
    • Latching or non-latching operation, selectable
    • One common DPDT contact outputs, normally energized or normally de-energized operation
    • 12 Additional SPST contacts, one for each channel, N/O or N/C
    • History memory storing up to 300 timestamped events in non-volatile memory
  • Applications: EDS490 Series

    • AC systems, single- and three-phase
    • Pure DC and mixed AC/DC systems
    • Distribution systems requiring fast ground fault location
    • UPS systems and battery systems
    • Systems with variable frequency drives (VFDs)
    • Systems with power conversion components, including rectifiers and inverters
    • Large industrial systems
    • Ungrounded systems with high leakage capacitances
  • Ordering information: EDS490 Series

    NameResponse ValueDisplay typeSupply VoltageOrdering Number
    EDS490-D-12 - 10 mA DigitalAC 16 - 72 V (42 - 460 Hz) DC 16 - 94 V B91080009
    EDS490-D-22 - 10 mA DigitalAC 70 - 276 V (42 - 460 Hz) DC 70 - 276 V B91080010
    EDS490-L-12 - 10 mA AnalogAC 16 - 72 V (42 - 460 Hz) DC 16 - 94 V B91080011
    EDS490-L-22 - 10 mA AnalogAC 70 - 276 V (42 - 460 Hz) DC 70 - 276 V B91080012
  • Downloads: EDS490 Series

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    EDS460 / EDS490 Series
    English 03.2011
    Download
    Installation Bulletin
    EDS460 / EDS490 Series
    English 10.2011
    Download
    User Manual
    EDS460 / EDS490 Series
    English 03.2011
    Download
    Brochure
    Overview of Products
    English 02.2014
    Download
  • Accessories: EDS490 Series

    Remote Communication Systems

    Ethernet and Modbus/TCP communication gateway for BENDER devices

    NameOrdering Number
    COM460IPB95061010
    COM461MTB95061021
    COM462RTUB95061022
    AC Current Transformers

    Current transformers for RCM and RCMS series ground fault monitors (AC only systems)

    NameOrdering Number
    W0-S20B911787
    W1-S35B911731
    W2-S70B911732
    W3-S105B911733
    W4-S140B911734
    W5-S210B911735
    Rectangular AC Current Transformers

    Rectangular current transformers for RCM and RCMS series ground fault monitors (AC only systems)

    NameOrdering Number
    WR70x175B98080609
    WR115x305B98080610
    Split-Core AC Current Transformers

    Split-core current transformers for RCM and RCMS series ground fault monitors (AC only systems)

    NameOrdering Number
    WS20x30B98080601
    WS50x80B98080603
    WS80x120B98080606
  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • EDS461 Series

    Ground fault location module for small ungrounded AC/DC systems

    The EDS461 ground fault location module, in combination with the appropriate ground fault detector, locates branch faults in ungrounded AC/DC systems. Up to 12 separate branches may be monitored by one EDS461 device. Up to 90 EDS devices may be connected together, for a total of 1080 branches simultaneously monitored. The EDS461 works on both AC and DC systems, including systems with variable frequency drives (VFDs). Devices are interconnected via RS-485 to automate the process of locating faults. An LCD display shows which branch has the ground fault after it has been located. One common DPDT contact is built into the EDS460.

    The EDS461 is used with the IRDH575 ground detector or LIM2010 line isolation monitor, and is designed for small control networks or isolated power systems. It features a common DPDT contact output.

  • Key Features: EDS461 Series

    • Ground fault location in ungrounded AC/DC systems, when combined with IRDH575 ground detector or LIM2010 line isolation monitor
    • Up to 12 separate branches monitored from one device
    • All channels scanned in parallel
    • Works on pure AC, pure DC, and mixed AC/DC systems, including systems with variable frequency drives (VFDs)
    • Digital display showing readings in real-time
    • Easy-to-use, onboard menu for managing settings
    • Devices linked via RS-485 display alarm values across all interconnected devices
    • Automatic ground fault detection and location with IRDH575 / LIM2010 via RS-485
    • Automatic self-test
    • Built-in test and reset buttons
    • Connections for external test and reset
    • Latching or non-latching operation, selectable
    • One common DPDT contact outputs, normally energized or normally de-energized operation
    • History memory storing up to 300 timestamped events in non-volatile memory
  • Applications: EDS461 Series

    • AC systems, single- and three-phase
    • Pure DC and mixed AC/DC systems
    • Distribution systems requiring fast ground fault location
    • UPS systems and battery systems
    • Systems with variable frequency drives (VFDs)
    • Control networks and small distribution systems
    • Isolated power systems for healthcare facilities
  • Ordering information: EDS461 Series

    NameResponse ValueDisplay typeSupply VoltageOrdering Number
    EDS461-D-10.2 - 1 mA DigitalAC 16 - 72 V (42 - 460 Hz) DC 16 - 94 V B91080005
    EDS461-D-20.2 - 1 mA DigitalAC 70 - 276 V (42 - 460 Hz) DC 70 - 276 V B91080006
    EDS461-L-10.2 - 1 mA AnalogAC 16 - 72 V (42 - 460 Hz) DC 16 - 94 V B91080007
    EDS461-L-20.2 - 1 mA AnalogAC 70 - 276 V (42 - 460 Hz) DC 70 - 276 V B91080008
  • Downloads: EDS461 Series

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    EDS460 / EDS490 Series
    English 03.2011
    Download
    Installation Bulletin
    EDS460 / EDS490 Series
    English 10.2011
    Download
    User Manual
    EDS460 / EDS490 Series
    English 03.2011
    Download
    Brochure
    Overview of Products
    English 02.2014
    Download
    Brochure
    Isolated Power Systems Equipment
    English 10.2011
    Download
    3D STEP Drawing
    460 Series
    N/A 06.2013
    Download
  • Accessories: EDS461 Series

    AC Current Transformers

    Current transformers for use with EDS461/EDS491 ground fault location modules

    NameOrdering Number
    W20-8000B98080009
    W35-8000B98080017
    W60-8000B98080027
  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • EDS491 Series

    Ground fault location module for small ungrounded AC/DC systems

    The EDS491 ground fault location module, in combination with the appropriate ground fault detector, locates branch faults in ungrounded AC/DC systems. Up to 12 separate branches may be monitored by one EDS491 device. Up to 90 EDS devices may be connected together, for a total of 1080 branches simultaneously monitored. The EDS491 works on both AC and DC systems, including systems with variable frequency drives (VFDs). Devices are interconnected via RS-485 to automate the process of locating faults. An LCD display shows which branch has the ground fault after it has been located. One common DPDT contact is built into the EDS490, along with twelve separate SPST contacts, one for each channel.

    The EDS491 is used with the IRDH575 ground detector or LIM2010 line isolation monitor, and is designed for small control networks or isolated power systems. It features a common DPDT contact output and twelve SPST contact outputs, one for each channel.

  • Key Features: EDS491 Series

    • Ground fault location in ungrounded AC/DC systems, when combined with IRDH575 or LIM2010 ground detector
    • Up to 12 separate branches monitored from one device
    • All channels scanned in parallel
    • Works on pure AC, pure DC, and mixed AC/DC systems, including systems with variable frequency drives (VFDs)
    • Digital display showing readings in real-time
    • Easy-to-use, onboard menu for managing settings
    • Devices linked via RS-485 display alarm values across all interconnected devices
    • Automatic ground fault detection and location with IRDH575 via RS-485
    • Automatic self-test
    • Built-in test and reset buttons
    • Connections for external test and reset
    • Latching or non-latching operation, selectable
    • One common DPDT contact outputs, normally energized or normally de-energized operation
    • 12 Additional SPST contacts, one for each channel, N/O or N/C
    • History memory storing up to 300 timestamped events in non-volatile memory
  • Applications: EDS491 Series

    • AC systems, single- and three-phase
    • Pure DC and mixed AC/DC systems
    • Distribution systems requiring fast ground fault location
    • UPS systems and battery systems
    • Systems with variable frequency drives (VFDs)
    • Control networks and small distribution systems
    • Isolated power systems for healthcare facilities
  • Ordering information: EDS491 Series

    NameResponse ValueDisplay typeSupply VoltageOrdering Number
    EDS491-D-10.2 - 1 mA DigitalAC 16 - 72 V (42 - 460 Hz) DC 16 - 94 V B91080013
    EDS491-D-20.2 - 1 mA DigitalAC 70 - 276 V (42 - 460 Hz) DC 70 - 276 V B91080014
    EDS491-L-10.2 - 1 mA AnalogAC 16 - 72 V (42 - 460 Hz) DC 16 - 94 V B91080015
    EDS490-L-20.2 - 1 mA AnalogAC 70 - 276 V (42 - 460 Hz) DC 70 - 276 V B91080016
  • Downloads: EDS491 Series

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    EDS460 / EDS490 Series
    English 03.2011
    Download
    Installation Bulletin
    EDS460 / EDS490 Series
    English 10.2011
    Download
    User Manual
    EDS460 / EDS490 Series
    English 03.2011
    Download
    Brochure
    Overview of Products
    English 02.2014
    Download
    Brochure
    Isolated Power Systems Equipment
    English 10.2011
    Download
  • Accessories: EDS491 Series

    AC Current Transformers

    Current transformers for use with EDS461/EDS491 ground fault location modules

    NameOrdering Number
    W20-8000B98080009
    W35-8000B98080017
    W60-8000B98080027
  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • EDS3090PG

    Portable ground fault location system for ungrounded AC/DC systems

    The EDS3090PG is a portable ground fault location system for ungrounded AC and DC systems. The system utilizes an advanced measuring principle to locate ground faults down to the load level. The robust aluminum case includes the EDS190P ground fault evalulator, varying sizes of current clamps, and accessories.

    The EDS3090PG is designed to be a stand-alone portable location system and requires no other devices to operate.

  • Key Features: EDS3090PG

    • Portable ground fault location system for ungrounded AC/DC systems
    • Standalone system, no additional devices required
    • Can locate ground faults down to the load level
    • Advanced, digital hand-held meter for evaluating for ground faults
    • Visual and audible alarms on hand-held meter
  • Applications: EDS3090PG

    • AC systems, single- and three-phase
    • Pure DC and mixed AC/DC systems
    • Distribution systems requiring fast ground fault location
    • UPS systems and battery systems
    • Systems with variable frequency drives (VFDs)
    • Systems with power conversion components, including rectifiers and inverters
    • Large industrial systems
  • Ordering information: EDS3090PG

    NameResponse ValueSupply VoltageOrdering Number
    EDS3090PG10 - 25 mA AC 230 V (50 - 60 Hz) B91082021
    EDS3090PG-1310 - 25 mA AC 90 - 132 V (50 - 60 Hz) B91082022
    EDS3091PG1 - 2.5 mA AC 230 V (50 - 60 Hz) B91082023
    EDS3091PG-131 - 2.5 mA AC 90 - 132 V (50 - 60 Hz) B91082024
  • Downloads: EDS3090PG

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    EDS3090 Series
    English 08.2013
    Download
    Installation Bulletin
    EDS3090 Series
    English 08.2013
    Download
    User Manual
    EDS3090 Series
    English 03.2013
    Download
    Brochure
    Overview of Products
    English 02.2014
    Download
  • Accessories: EDS3090PG

  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • EDS3090

    Portable ground fault location system for ungrounded AC/DC systems

    The EDS3090 is a portable ground fault location system for ungrounded AC and DC systems. The system utilizes an advanced measuring principle to locate ground faults down to the load level. The robust aluminum case includes the EDS190P ground fault evalulator, varying sizes of current clamps, and accessories.

    The EDS3090 is designed for use with BENDER's installed IRDH575 ground fault detector.

  • Key Features: EDS3090

    • Portable ground fault location system for ungrounded AC/DC systems
    • Works with BENDER's IRDH575 ground fault detector to assist in automating the ground fault location process
    • Can locate ground faults down to the load level
    • Advanced, digital hand-held meter for evaluating for ground faults
    • Visual and audible alarms on hand-held meter
  • Applications: EDS3090

    • AC systems, single- and three-phase
    • Pure DC and mixed AC/DC systems
    • Distribution systems requiring fast ground fault location
    • UPS systems and battery systems
    • Systems with variable frequency drives (VFDs)
    • Systems with power conversion components, including rectifiers and inverters
    • Large industrial systems
  • Ordering information: EDS3090

    NameResponse ValueOrdering Number
    EDS309010 - 25 mA B91082026
    EDS30911 - 2.5 mA B91082027
  • Downloads: EDS3090

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    EDS3090 Series
    English 08.2013
    Download
    Installation Bulletin
    EDS3090 Series
    English 08.2013
    Download
    User Manual
    EDS3090 Series
    English 03.2013
    Download
    Brochure
    Overview of Products
    English 02.2014
    Download
  • Accessories: EDS3090