    Isolated power panels with line isolation monitor for healthcare facilities

    BENDER's standard hospital panel provides isolated power service and protection to operating rooms and other critical care areas. Designed in strict compliance with UL 1047, UL 1022, and UL 50, BENDER isolated power panels offer the most up-to-date technology for all isolated power distribution requirements. Panels include:

    • Isolation transformer, rated to your requirements
    • Primary circuit breaker
    • Eight (8) 2-pole circuit breakers, field expandable to 16
    • LIM2010 line isolation monitor

    A wide range of additional features and options are available, including:

    • Provision(s) for receptacles and/or ground jacks
    • Circuit control via PLC
    • Integrated ground fault location system
    • Transformer load monitoring
    • Remote communication system integration
  • Key Features: Isolated Power Panels

    • No interference with electrical equipment
    • Special phase-locking circuitry for ultimate stability and repeatability
    • Versions for 2 mA and 5 mA trip level
    • Seven-segment display for THC, digital display for text, and LED bar graph
    • Additional alarms for transformer overload and overtemperature, voltage, and more
    • Visual and audible alarm indications
    • Provision for remote indicators
    • Connects to optional BENDER communication network
    • Controls optional ground fault location system
    • History memory
  • Applications: Isolated Power Panels

    • Isolated power systems
    • Healthcare facilities
  • Ordering information: Isolated Power Panels

    Refer to technical bulletin / datasheet for information on ordering.
  • Downloads: Isolated Power Panels

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    Isolated Power Panels
    English 01.2012
    Download
    User Manual
    Isolated Power Panels
    English 04.2013
    Download
    Technical Bulletin / Datasheet
    LIM2010
    English 02.2011
    Download
    Installation Bulletin
    LIM2010
    English 11.2012
    Download
    User Manual
    LIM2010
    English 02.2013
    Download
    Brochure
    Isolated Power Systems Equipment
    English 10.2011
    Download
    User Manual
    Isolated Power Panels
    Spanish 06.2014
    Download
  • Accessories: Isolated Power Panels

  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • Dual System Panels

    Dual system isolated power panels for healthcare facilities

    BENDER's standard hospital panel provides isolated power service and protection to operating rooms and other critical care areas. Designed in strict compliance with UL 1047, UL 1022, and UL 50, BENDER isolated power panels offer the most up-to-date technology for all isolated power distribution requirements. Panels include:

    • Isolation transformer, rated to your requirements
    • Primary circuit breaker
    • Eight (8) 2-pole circuit breakers, field expandable to 16
    • LIM2010 line isolation monitor

    A wide range of additional features and options are available, including:

    • Provision(s) for receptacles and/or ground jacks
    • Circuit control via PLC
    • Integrated ground fault location system
    • Transformer load monitoring
    • Remote communication system integration
  • Key Features: Dual System Panels

    • No interference with electrical equipment
    • Special phase-locking circuitry for ultimate stability and repeatability
    • Versions for 2 mA and 5 mA trip level
    • Seven-segment display for THC, digital display for text, and LED bar graph
    • Additional alarms for transformer overload and overtemperature, voltage, and more
    • Visual and audible alarm indications
    • Provision for remote indicators
    • Connects to optional BENDER communication network
    • Controls optional ground fault location system
    • History memory
  • Applications: Dual System Panels

    • Isolated power systems
    • Healthcare facilities
  • Ordering information: Dual System Panels

    Refer to technical bulletin / datasheet for information on ordering.
  • Downloads: Dual System Panels

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    Isolated Power Panels
    English 01.2012
    Download
    User Manual
    Isolated Power Panels
    English 04.2013
    Download
    Technical Bulletin / Datasheet
    LIM2010
    English 02.2011
    Download
    Installation Bulletin
    LIM2010
    English 11.2012
    Download
    User Manual
    LIM2010
    English 02.2013
    Download
    Brochure
    Isolated Power Systems Equipment
    English 10.2011
    Download
    User Manual
    Isolated Power Panels
    Spanish 06.2014
    Download
  • Accessories: Dual System Panels

  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • Dual Voltage Panels

    Dual output voltage isolated power panels for healthcare facilities

    BENDER's standard hospital panel provides isolated power service and protection to operating rooms and other critical care areas. Designed in strict compliance with UL 1047, UL 1022, and UL 50, BENDER isolated power panels offer the most up-to-date technology for all isolated power distribution requirements. Panels include:

    • Isolation transformer, rated to your requirements
    • Primary circuit breaker
    • Eight (8) 2-pole circuit breakers, field expandable to 16
    • LIM2010 line isolation monitor

    A wide range of additional features and options are available, including:

    • Provision(s) for receptacles and/or ground jacks
    • Circuit control via PLC
    • Integrated ground fault location system
    • Transformer load monitoring
    • Remote communication system integration
  • Key Features: Dual Voltage Panels

    • No interference with electrical equipment
    • Special phase-locking circuitry for ultimate stability and repeatability
    • Versions for 2 mA and 5 mA trip level
    • Seven-segment display for THC, digital display for text, and LED bar graph
    • Additional alarms for transformer overload and overtemperature, voltage, and more
    • Visual and audible alarm indications
    • Provision for remote indicators
    • Connects to optional BENDER communication network
    • Controls optional ground fault location system
    • History memory
  • Applications: Dual Voltage Panels

    • Isolated power systems
    • Healthcare facilities
  • Ordering information: Dual Voltage Panels

    Refer to technical bulletin / datasheet for information on ordering.
  • Downloads: Dual Voltage Panels

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    Isolated Power Panels
    English 01.2012
    Download
    User Manual
    Isolated Power Panels
    English 04.2013
    Download
    Technical Bulletin / Datasheet
    LIM2010
    English 02.2011
    Download
    Installation Bulletin
    LIM2010
    English 11.2012
    Download
    User Manual
    LIM2010
    English 02.2013
    Download
    Brochure
    Isolated Power Systems Equipment
    English 10.2011
    Download
    User Manual
    Isolated Power Panels
    Spanish 06.2014
    Download
  • Accessories: Dual Voltage Panels

  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • LIM2010

    Digital line isolation monitor for isolated power systems

    The LIM2010 line isolation monitor (LIM) measures the total hazard current (THC) in an isolated power system. The LIM2010 is a full-featured device which includes a seven-segment display, digital display, and easy-to-read LED bar graph, connection monitoring, and compatibility with BENDER's ground fault location system and communication network. The LIM2010 may be configured for additional alarms, including transformer overload and overtemperature, overvoltage and undervoltage, and more. The LIM2010 has an automatic self-calibration and self-check feature. Multiple LIM2010 devices may also be controlled by a single, intellgent remote station. The LIM2010 is intended for use as part of an isolated power system that conforms with the applicable requirements of ANSI/NFPA 99, ANSI/NFPA 70, and CAN/CSA-C22.2 No. 29-M1989.

  • Key Features: LIM2010

    • No interference with electrical equipment
    • Special phase-locking circuitry for ultimate stability and repeatability
    • Versions for 2 mA and 5 mA trip level
    • Seven-segment display for THC, digital display for text, and LED bar graph
    • Additional alarms for transformer overload and overtemperature, voltage, and more
    • Visual and audible alarm indications
    • Provision for remote indicators
    • Connects to optional BENDER communication network
    • Controls optional ground fault location system
    • History memory
  • Applications: LIM2010

    • Isolated power systems
    • Healthcare facilities
  • Ordering information: LIM2010

    NameSystem VoltageOrdering Number
    LIM2010AC 100 - 240 V (50 - 60 Hz) B92075021
  • Downloads: LIM2010

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    LIM2010
    English 02.2011
    Download
    Installation Bulletin
    LIM2010
    English 11.2012
    Download
    User Manual
    LIM2010
    English 02.2013
    Download
    Brochure
    Isolated Power Systems Equipment
    English 10.2011
    Download
    Technical Bulletin / Datasheet
    LIM2010
    Spanish 05.2013
    Download
    User Manual
    LIM2010
    Spanish 06.2014
    Download
  • Accessories: LIM2010

    Ground Fault Location Modules

    Ground fault location module for small ungrounded AC/DC systems

    NameOrdering Number
    EDS461-D-1B91080005
    EDS461-D-2B91080006
    EDS461-L-1B91080007
    EDS461-L-2B91080008
    EDS491-D-1B91080013
    EDS491-D-2B91080014
    EDS491-L-1B91080015
    EDS490-L-2B91080016
    Remote Communication Systems

    Ethernet and Modbus/TCP communication gateway for BENDER devices

    NameOrdering Number
    COM460IPB95061010
    COM461MTB95061021
    COM462RTUB95061022
    Remote Indicators

    Remote Indicators for LIM2010 Line Isolation Monitor

    NameOrdering Number
    MK2000-G1B521300002
    MK2000-G2B521300007
    MK2000P-G1B521300188
    MK2000C-G1B521300188
    MK2000CP-G1B521300020
    MK2000CBMB521300022
    MK2000CBMB521300022
    MK2430-12B95100002
    MK2430-11B95100001
    MK2430A-12B95100006
    MK2430A-11B95100005
    MK2430-12RSB521301096
    MK2430-11RSB521301095
    MK800-11B95100100
    MK800-12B95100101
    MK800A-11B95100102
    MK800A-12B95100103
    MK800E-11B95100105
    MK800E-12B95100106
    MK800-11RSB521301093
    MK800-12RSB521301094
  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • STW Series

    Load monitoring current transformers for LIM2010 line isolation monitor

    STW series current transformers are combined with the LIM2010 line isolation monitor to provide load current and transformer overload monitoring in isolated power systems for healthcare facilities. STW3 models may be used on systems with up to 100 A of load current. STW4 models may be used for up to 200 A of load current.
  • Key Features: STW Series

  • Applications: STW Series

  • Ordering information: STW Series

    NameDiameter of openingMax. load ampsOrdering Number
    STW30.7" (18 mm)100 AB98021000
    STW40.7" (18 mm)200 AB98021001
  • Downloads: STW Series

    Document Name Language Date Download
    Installation Bulletin
    STW3 and STW4
    English 05.2012
    Download
    Technical Bulletin / Datasheet
    LIM2010
    English 02.2011
    Download
    Brochure
    Isolated Power Systems Equipment
    English 10.2011
    Download
  • Accessories: STW Series

  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • LT3000

    Line Isolation Monitor (LIM) and GFCI Tester

    NFPA 99 requires that line isolation monitor (LIM) and ground fault circuit interrupter (GFCI) tests be conducted at regular intervals. The LT3000 is an effective and versatile testing instrument for easily fufilling these requirements.

    The LT3000 plugs into any wall outlet up to 240 V, 50 or 60 Hz. A simple pretest confirms the integrity of the isolated power system and to ensure that the system is properly grounded. In the standard view, the LCD display shows the system voltage. In LIM/GFCI testing mode, adjust the current until it reads 2, 5 or 6 mA on the LCD display. Alternately pushing the L1 and L2 buttons confirms that the LIM / GFCI is operating correctly.

  • Key Features: LT3000

    • Tests line isolation monitors and ground fault circuit interrupters
    • Operates on system voltages from 100 - 240 VAC
    • Large digital LCD display
    • Overload protection with automatic reset
    • Easy to clean, rugged lexan front foil
    • System leakage measurements
    • Twist-to-lock adapter
    • Lightweight (less than 1 lb)
  • Applications: LT3000

    • Testing line isolation monitors in isolated power systems in healthcare facilities
    • Testing ground fault circuit interrupters in healthcare facilities
  • Ordering information: LT3000

    NameAccessories IncludedOrdering Number
    LT3000 KitNoneB521300004
    LT3000 SetCarrying case, adapter for 2300HG receptacleB521300295
  • Downloads: LT3000

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    LT3000
    English 09.2012
    Download
  • Accessories: LT3000

  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • ZT1590

    Digital Clock and Timer

    The ZT1590 digital clock and timer is a complete, microprocessor-based device that displays both time of day and elapsed time information. The ZT1590 has a dual-row, 7-segment display with large, red LED characters, easily read in high ambient light. All features, as well as the device setup, may be carried out with the four, onboard pushbuttons, or on an optionally connected MK1550 clock remote. No DIP switch configuration is required.

    The digital clock on the ZT1590 may be set to 12 hour or 24 hour mode. The time is displayed on the top display. If power is lost to the device, the clock will continue to run (with the display inactive) for at least 24 hours, without loss of time. The elapsed timer begins in minutes/seconds, and will automatically switch over to hours/minutes after reaching 59:59.

    The ZT1590 is a very low-profile device, with a depth of only slightly over 1". An external class 2 power supply (sold separately or as part of a kit) is available, allowing the ZT1590 to be powered by 100-240 VAC. Refer to ZT1590S for a complete, preassembled kit in backbox.

  • Key Features: ZT1590

    • 12/24 hour clock time
    • Elapsed time in minutes/seconds automatically carried over to hours/minutes
    • All device set up and features carried out via connected MK1550 chronometer remote
    • Plugable connectors for simple installation
    • Utilizes external class 2 power supply for low voltage power
    • Power outage backup for at least 24 hours, no batteries required
  • Applications: ZT1590

    • Isolated power systems
    • Healthcare facilities
  • Ordering information: ZT1590

    NameOrdering Number
    ZT1590B511100012
  • Downloads: ZT1590

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    Clocks and Timers
    English 8.2014
    Download
    Installation Bulletin
    ZT1590 / MK1550
    English 08.2014
    Download
  • Accessories: ZT1590

    Power Supplies

    Class 2 Power Supply

    NameOrdering Number
    CP-D12083P13800050
    Remote Indicators

    Clock Remote for BENDER Digital Clocks / Timers

    NameOrdering Number
    MK1550B511100019
  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • ZT1590RS

    Preassembled Digital Clock and Timer Kit

    The ZT1590 digital clock and timer is a complete, microprocessor-based device that displays both time of day and elapsed time information. The ZT1590 has a dual-row, 7-segment display with large, red LED characters, easily read in high ambient light. All features, as well as the device setup, may be carried out with the four, onboard pushbuttons, or on an optionally connected MK1550 clock remote. No DIP switch configuration is required.

    The digital clock on the ZT1590 may be set to 12 hour or 24 hour mode. The time is displayed on the top display. If power is lost to the device, the clock will continue to run (with the display inactive) for at least 24 hours, without loss of time. The elapsed timer begins in minutes/seconds, and will automatically switch over to hours/minutes after reaching 59:59.

    The ZT1590RS is a preassembled kit with clock and power supply, in a backbox with front trim. Refer to ZT1590 for standalone clock and components.

  • Key Features: ZT1590RS

    • 12/24 hour clock time
    • Elapsed time in minutes/seconds automatically carried over to hours/minutes
    • All device set up and features carried out via connected MK1550 chronometer remote
    • Plugable connectors for simple installation
    • Utilizes external class 2 power supply for low voltage power
    • Power outage backup for at least 24 hours, no batteries required
    • Preassembled kit including clock and power supply in backbox with front trim
  • Applications: ZT1590RS

    • Isolated power systems
    • Healthcare facilities
  • Ordering information: ZT1590RS

    NameOrdering Number
    ZT1590RSB521300297
  • Downloads: ZT1590RS

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    Clocks and Timers
    English 8.2014
    Download
    Installation Bulletin
    ZT1590 / MK1550
    English 08.2014
    Download
  • Accessories: ZT1590RS

    Remote Indicators

    Clock Remote for BENDER Digital Clocks / Timers

    NameOrdering Number
    MK1550B511100019
  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • ZT1594

    Surgical Chronometer

    The ZT1594 surgical chronometer is a complete, microprocessor based system that displays time of day and three elapsed times. The system has four seven-segment displays with large, red LED characters easily read in high ambient light. All features, as well as device setup, are carried out on the connected MK1554 chronometer remote.

  • Key Features: ZT1594

    • 12/24 hour clock time
    • Elapsed time in minutes/seconds automatically carried over to hours/minutes
    • All device set up and features carried out via connected MK1554 chronometer remote
    • Plugable connectors for simple installation
    • 100 - 240 VAC supply power input
    • Power outage backup for at least 24 hours, no batteries required
  • Applications: ZT1594

    • Isolated power systems
    • Healthcare facilities
  • Ordering information: ZT1594

    NameOrdering Number
    ZT1594B511100012
  • Downloads: ZT1594

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    Clocks and Timers
    English 8.2014
    Download
  • Accessories: ZT1594

  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • MK1550

    Clock Remote for BENDER Digital Clocks / Timers

    The MK1550 is a clock remote for use with the ZT1590 digital clock and timer. The MK1550 duplicates all functions of the ZT1590 and may be installed in a remote location. The clock may also be set up using the MK1550's four pushbuttons. The timer pushbuttons may be used to pause, resume or reset an elapsed timer when desired. The HOLD/RESUME pushbutton is supplied with a red LED, which flashes when the count is paused.

    The MK1550 mounts in a standard single-gang electrical box.

  • Key Features: MK1550

    • Duplicates all pushbutton and setup features of connected clocks, timers, and chronometers
    • Mounts in standard single-gang electrical box
  • Applications: MK1550

  • Ordering information: MK1550

    NameOrdering Number
    MK1550B511100019
  • Downloads: MK1550

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    Clocks and Timers
    English 8.2014
    Download
    Installation Bulletin
    ZT1590 / MK1550
    English 08.2014
    Download
  • Accessories: MK1550

  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • XM Series

    Hospital Grade Isolation Transformers

    BENDER's hospital grade isolation transformers provide isolation between configured primary and secondary voltages. Standard single-phase transformers are configured at the factory for a single primary voltage and a single secondary voltage. Dual secondary transformers are configured at the factory for a single primary voltage, a secondary voltage, and an additional secondary voltage rated for 120 VAC.

    BENDER isolation transformers are intended for use as a part of an isolated power system. Refer to BENDER's line of isolated power panels for more information.

  • Key Features: XM Series

    • Single-phase, copper-wound transformers with primary and secondary voltages configured at the factory
    • Power rating configurable up to 25 kVA
    • Class H rated insulation
    • Electrostatic shield between primary and secondary windings, grounded to enclosure
    • Maximum 37 dB sound level
    • Maximum leakage current in compliance with UL 1047 (tables 30.1 and 30.2) and CSA Z32.2
    • Mounting hardware provided for simple installation
  • Applications: XM Series

    • Isolated power systems
    • Healthcare facilities
  • Ordering information: XM Series

    Refer to technical bulletin / datasheet for information on ordering.
  • Downloads: XM Series

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    Isolation Transformers
    English 08.2011
    Download
    User Manual
    Isolated Power Panels
    English 04.2013
    Download
    Brochure
    Isolated Power Systems Equipment
    English 10.2011
    Download
  • Accessories: XM Series

  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • GPM Series

    Ground power modules for healthcare facilities

    BENDER series GPM ground and power modules provide a combination of hospital grade power receptacles and/or ground jacks to satisfy the requirements of general and critical care areas. Straight blade (single or duplex) and twist-to-lock receptacles may be provided. Also available are hospital grade ground cords to facilitate the implementation of an equipotential environment.

    Ground and power modules are designed in strict compliance with UL467, UL50, the NFPA 70 (National Electric Code), and NFPA 99.

  • Key Features: GPM Series

    • Hospital grade outlet devices for supply and grounding of portable equipment
    • May contain hospital grade power receptacles, hospital grade ground jacks, and/or aluminum or copper ground buses
    • Available for flush or surface mounted applications
  • Applications: GPM Series

    • Isolated power systems
    • Healthcare facilities
  • Ordering information: GPM Series

    Refer to technical bulletin / datasheet for information on ordering.
  • Downloads: GPM Series

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    Ground Power Modules
    English 04.2011
    Download
    Brochure
    Isolated Power Systems Equipment
    English 10.2011
    Download
  • Accessories: GPM Series

  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • XRM Series

    X-ray / laser receptacle modules for healthcare facilities

    BENDER XRM series x-ray/laser receptacle modules provide a convenient source of power for portable x-ray and laser equipment. Designed in strict compliance with UL standards, the XRM modules are a high quality outlet device accessory that is fully compatible with BENDER isolated power panels.

    Type XRM modules include power receptacle which matches the NEMA plug configuration of the x-ray or laser equipment. In addition, the module may include a remote alarm indicator for the connected line isolation monitor at the isolated power panel. The associated isolated power panel will have a programmable logic controller (PLC) that works in tandem with the module to activate or deactivate the receptacle.

  • Key Features: XRM Series

    • Modules with flush or surface mounted receptacles for use with x-ray and laser equipment
    • Available for flush- or surface-mounted applications
    • Available with door contacts, "in-use" lamp, and BENDER line isolation monitor remote indicator
  • Applications: XRM Series

    • Isolated power systems
    • Healthcare facilities
  • Ordering information: XRM Series

    Refer to technical bulletin / datasheet for information on ordering.
  • Downloads: XRM Series

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    XRM Series
    English 05.2014
    Download
    Brochure
    Isolated Power Systems Equipment
    English 10.2011
    Download
  • Accessories: XRM Series

  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • HGC and HGJ Series

    Hospital grade ground jacks and ground cords

    HGC and HGJ models are hospital grade outlet devices for the supply and grounding of portable equipment. Various lengths are available for ground cords, featuring highly flexible wire with a heavy duty clip or lug at one end. Products are UL listed to UL 1047.

  • Key Features: HGC and HGJ Series

    • Applications - Hospital Grade outlet devices for supply and grounding of portable equipment
    • Hospital Ground Cords: various lengths available and highly flexible wire with a heavy duty clip or lug and Hospital Ground Jacks
    • Standards - UL Listed Product (UL 1047)
  • Applications: HGC and HGJ Series

    • Isolated power systems
    • Healthcare facilities
  • Ordering information: HGC and HGJ Series

    Refer to technical bulletin / datasheet for information on ordering.
  • Downloads: HGC and HGJ Series

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    Ground Power Modules
    English 04.2011
    Download
    Brochure
    Isolated Power Systems Equipment
    English 10.2011
    Download
  • Accessories: HGC and HGJ Series