  • 9604 Series

    Analog output meters for BENDER devices

    The 9604/7204 meters are panel-mounted external devices that connect to various BENDER devices. These meters are designed to display either the insulation resistance (for various IR... devices) or ground fault current (for various RCM... devices) of the system.
  • Key Features: 9604 Series

  • Applications: 9604 Series

  • Ordering information: 9604 Series

    NameInput currentDimensionsCompatible IR... devicesCompatible RCM... devicesOrdering Number
    7204-14210... 400 μF2.83" x 2.83" (72 mm x 72 mm)IR470LY, IR475LY, IRDH275, IRDH375B986763
    9604-14210... 400 μF3.78" x 3.78" (96 mm x 96 mm)IR470LY, IR475LY, IRDH275, IRDH375B986764
    7204-42410... 400 μF2.83" x 2.83" (72 mm x 72 mm)RCM47..., RCMA47..., RCM420-DM...B986805
    9604-42410... 400 μF3.78" x 3.78" (96 mm x 96 mm)RCM47..., RCMA47..., RCM420-DM...B986807
  • Downloads: 9604 Series

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    Remote Indicators for Industrial Use
    English 03.2012
    Download
  • Accessories: 9604 Series

  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • MK2000 Series

    Remote Indicators for LIM2010 Line Isolation Monitor

    MK series remote indicators are designed for use with the BENDER LIM2010 Line Isolation Monitor. A remote indicator duplicates audible and visual alarm indications on the LIM. All remote indicators include a green “SAFE” LED, a red “HAZARD” LED, and a “MUTE” button with an integral amber LED. The “MUTE” button is used to silence the remote audible alarm. Optionally, it can also be used to silence all audible alarms in the system.

    Optional features include a test button, overload alarm LED, and digital display. Refer to ordering information for more details.

    MK2000 series indicators are compatible with the LIM2010.

  • Key Features: MK2000 Series

    • LED display for long life
    • No interference with medical equipment
    • Interfaces with all BENDER line isolation monitors, including the LIM2010
    • Uses low voltage wiring (12 VDC or 12 VAC)
    • Mounts to standard electrical gang box
    • Connection via screw terminal strip
    • Easy-to-clean, rugged stainless steel and lexan front foil
    • Options include test button, overload alarm LED, and digital display showing real-time THC readings
  • Applications: MK2000 Series

  • Ordering information: MK2000 Series

    NameTest buttonOverload LEDDigital displaySizeOrdering Number
    MK2000-G1One gangB521300002
    MK2000-G2Two gangB521300007
    MK2000P-G1One gangB521300188
    MK2000C-G1One gangB521300188
    MK2000CP-G1One gangB521300020
    MK2000CBMTwo gangB521300022
  • Downloads: MK2000 Series

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    Remote Indicators for Hospitals
    English 04.2011
    Download
    Installation Bulletin
    MK2000(C)(P) Series
    English 11.2012
    Download
    Brochure
    Isolated Power Systems Equipment
    English 10.2011
    Download
  • Accessories: MK2000 Series

  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • MK2000CBM

    Digital Remote Indicator for LIM2010 Line Isolation Monitor

    The MK2000CBM is a digital remote indicator for use with the BENDER LIM2010 Line Isolation Monitor. The MK2000CBM duplicates audible and visual alarm indications on the LIM. The remote includes the following features:

    • Green "SAFE" LED, red "HAZARD" LED, and yellow "MUTE" LED
    • Mute button to silence audible alarm
    • Test button to initiate self-test of connected LIM
    • Digital display showing the THC of the connected LIM in real-time
    • Digital display showing transformer overload in real-time
    • Two-wire RS-485 connection for digital communication
  • Key Features: MK2000CBM

    • LED display for long life
    • No interference with medical equipment
    • Interfaces with all BENDER line isolation monitors, including the LIM2010
    • Uses low voltage wiring (12 VDC or 12 VAC)
    • Mounts to standard electrical gang box
    • Connection via screw terminal strip
    • Easy-to-clean, rugged stainless steel and lexan front foil
    • Safe, hazard, overload, and mute LEDs
    • Mute and test pushbuttons
    • Digital displays showing THC and overload readings in real-time
  • Applications: MK2000CBM

  • Ordering information: MK2000CBM

    NameTest buttonOverload LEDDigital displaySizeOrdering Number
    MK2000CBMTwo gangB521300022
  • Downloads: MK2000CBM

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    Remote Indicators for Hospitals
    English 04.2011
    Download
    Installation Bulletin
    MK2000CBM
    English 11.2012
    Download
    Brochure
    Isolated Power Systems Equipment
    English 10.2011
    Download
  • Accessories: MK2000CBM

  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • RAS Series

    Remote Annunciator Station for Line Isolation Monitors

    RAS series remote annunciator stations utilize multiple MK series remote indicators, each connected to a line isolation monitor. Included remote indicators may feature a built-in test button and a transformer overload LED. Each remote indicator is powered directly by the LIM2010 line isolation monitor, located at the isolated power panel.

    RAS stations utilize MK2000 series remote indicators. Refer to the MK2000 for more information on available models.

  • Key Features: RAS Series

  • Applications: RAS Series

  • Ordering information: RAS Series

    Refer to technical bulletin / datasheet for information on ordering.
  • Downloads: RAS Series

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    Remote Indicators for Hospitals
    English 04.2011
    Download
    Brochure
    Isolated Power Systems Equipment
    English 10.2011
    Download
  • Accessories: RAS Series

  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • MK2430

    Remote indicating station for BENDER devices

    The MK2430 is an all-in-one remote indicating station for visual and audible indication of multiple connected BENDER devices. The MK2430 displays information regarding each individual device, system, or room and can define custom labels based on each individual application. A complete system test may also be done from the device.

    Compatible devices include IRDH series ground detectors, RCMS series ground fault monitors, the LIM2010 line isolation monitor; and EDS series ground fault location modules.

  • Key Features: MK2430

    • Digital display showing operating messages and alarms for all connected devices
    • Backlit LCD display
    • Predefined texts in 20 languages
    • 200 freely programmable message texts including location labels
    • Audible alarm with mute button
    • Settings modified via easy-to-use onboard menu
    • Flush and surface mountable
    • Option for 12 digital inputs
    • Stores up to 250 timestamped alarms
    • Supports IRDH series ground detectors, RCMS series ground fault monitors, the LIM2010 line isolation monitor, and EDS series ground fault location modules
  • Applications: MK2430

  • Ordering information: MK2430

    NameDigital inputsMountingOrdering Number
    MK2430-12Flush mountedB95100002
    MK2430-11Flush mountedB95100001
    MK2430A-12Surface mountedB95100006
    MK2430A-11Surface mountedB95100005
    MK2430-12RSPreassembled in backbox with SS front trimB521301096
    MK2430-11RSPreassembled in backbox with SS front trimB521301095
  • Downloads: MK2430

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    Remote Indicators for Industrial Use
    English 03.2012
    Download
    Technical Bulletin / Datasheet
    Remote Indicators for Hospitals
    English 04.2011
    Download
    User Manual
    MK2430
    English 08.2012
    Download
  • Accessories: MK2430

  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • MK800

    Remote station for BENDER devices

    The MK800 is an all-in-one remote station for visual and audible indication of large-scale networks of BENDER devices. The MK800 utilizes a large, backlit LCD display to display information regarding each individual connected device, system, or area. Custom labels can be defined for individual applications. A detailed history memory shows up to 1000 timestamped events. The MK800 utilizes both internal and external RS-485 networks to deploy and control large-scale networks of BENDER devices from a single location.

    Compatible devices include IRDH series ground detectors, RCMS series ground fault monitors, the LIM2010 line isolation monitor, and EDS series ground fault location modules.

  • Key Features: MK800

    • Digital display showing operating messages and alarms for all connected devices
    • Backlit LCD display
    • Predefined texts in 20 languages
    • 200 freely programmable message texts including location labels
    • Audible alarm with mute button
    • Settings modified via easy-to-use onboard menu
    • Flush and surface mountable
    • Option for 12 digital inputs
    • Stores up to 250 timestamped alarms
    • Supports IRDH series ground detectors, RCMS series ground fault monitors, the LIM2010 line isolation monitor, and EDS series ground fault location modules
  • Applications: MK800

  • Ordering information: MK800

    NameDigital inputsMountingOrdering Number
    MK800-11Flush mountedB95100100
    MK800-12Flush mountedB95100101
    MK800A-11Surface mountedB95100102
    MK800A-12Surface mountedB95100103
    MK800E-11No enclosureB95100105
    MK800E-12No enclosureB95100106
    MK800-11RSPreassembled in backbox with SS front trimB521301093
    MK800-12RSPreassembled in backbox with SS front trimB521301094
  • Downloads: MK800

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    Remote Indicators for Industrial Use
    English 03.2012
    Download
    Technical Bulletin / Datasheet
    Remote Indicators for Hospitals
    English 04.2011
    Download
    User Manual
    MK800
    English 07.2009
    Download
  • Accessories: MK800